Skip to main content

Specialized tube type

Specialized - Radiation Counter vacuum tubes

Specialized - Radiation Counter records in Tube Tinker cover 119 tube designations, including 211 preserved original datasheets. Compare bases, sockets, heater requirements, construction, exact variations, and directional replacement options.

Search this type in the catalog →
Tube records
119
Original datasheets
211
Variation families
2
Tubes with alternatives
0

About Specialized - Radiation Counter tubes

If the tube is described as a radiation counter / detector then apply this type.

Electrical range

Nominal heater voltage
0–6.3 V
Nominal heater current
0–1.85 A

Common specialized - radiation counter characteristics

These are the most frequently recorded attributes among tubes in this category.

Bases

  • 3PIN1
  • 9NX1

Sockets

  • A1825
  • B41
  • B9A1
  • IO1
  • MEDIUM71
  • SUBMINIATURE81

Constructions

  • GeigerMullerCounter85
  • IonizationChamber14
  • ProportionalCounter8
  • FissionCounter6
  • FissionIonizationDetector2
  • Rectifier2
  • Other1
  • RadiationDetectorOther1

Specialized - Radiation Counter tube list

Page 1 of 3

Open advanced catalog filters →
  • 100C

    GeigerMullerCounter

    Permanent-sensitivity argon-filled Geiger-Müller counter with a thin mica window for beta and X-ray detection. It operates around 1.2 kV and provides a broad counting plateau with approximately 200 µs dead time.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 100CB

    GeigerMullerCounter

    Permanent-sensitivity argon-filled Geiger-Müller counter with a thin mica window for beta and X-ray detection. The based version operates around 1.2 kV with a broad plateau and approximately 200 µs dead time.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 100N

    GeigerMullerCounter

    Neon-filled self-quenching Geiger-Müller counter with a thin mica window for beta detection. It operates around 700 V and provides a broad counting plateau with approximately 200 µs dead time.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 100NB

    GeigerMullerCounter

    Based version of the neon-filled self-quenching Geiger-Müller counter for beta detection, using a thin mica window and broad operating plateau for general radiation-counting instrumentation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 120C

    GeigerMullerCounter

    Gas-filled Geiger-Müller radiation counter designed for beta and X-ray detection, using a thin mica window and self-quenching fill for stable pulse counting in laboratory radiation instruments.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 120N

    GeigerMullerCounter

    Self-quenching gas-filled Geiger-Müller counter intended for beta-radiation detection, using a thin mica window and stable counting plateau for general laboratory and monitoring applications.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 120NB

    GeigerMullerCounter

    Based self-quenching Geiger-Müller counter intended for beta-radiation detection, combining a thin mica entrance window with gas-filled pulse-counting operation for laboratory radiation measurements.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 153C

    GeigerMullerCounter

    Gas-filled Geiger-Müller radiation counter for particle or photon detection, designed to produce discrete counting pulses over a stable operating plateau in radiation-measurement equipment.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18500

    GeigerMullerCounter

    Philips self-quenching Geiger-Müller radiation counter intended for ionizing-radiation measurement. Manufacturer data specify counting plateau, background, timing, life, and construction characteristics for laboratory instrumentation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18501

    GeigerMullerCounter

    Philips self-quenching Geiger-Müller counter for radiation measurement, with manufacturer specifications covering operating voltage, plateau behavior, background count, dead time, expected life, and detector construction.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18502

    GeigerMullerCounter

    Philips self-quenching Geiger-Müller radiation counter designed for pulse-counting measurement of ionizing radiation, with published operating plateau, background, timing, lifetime, and construction data.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18503

    GeigerMullerCounter

    Philips self-quenching Geiger-Müller radiation counter for ionizing-radiation measurement. Its manufacturer data characterize stable counting operation through specified threshold, plateau, background, timing, and detector-life limits.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18504

    GeigerMullerCounter

    Philips self-quenching Geiger-Müller radiation counter intended for ionizing-radiation measurement, with published characteristics for operating plateau, background count, dead time, expected life, and construction.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18505

    GeigerMullerCounter

    Self-quenching Philips mica-window Geiger-Müller counter for alpha, beta, and gamma measurement. Its thin window and halogen-quenched gas fill support broad radiation sensitivity with a long operating life.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18506

    GeigerMullerCounter

    Self-quenching Philips mica-window Geiger-Müller counter for alpha, beta, and gamma measurement. It combines a long operating plateau with halogen quenching and an enlarged sensitive window for radiation counting.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18509

    GeigerMullerCounter

    Miniature self-quenching Philips Geiger-Müller counter for gamma and high-energy beta radiation. Its compact cathode and low background suit small radiation-monitoring and counting instruments.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 1850902

    GeigerMullerCounter

    18509/02 miniature self-quenching Geiger-Müller counter for gamma and high-energy beta radiation. This variant provides a short dead time and compact construction for relatively high-rate radiation counting.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18510

    GeigerMullerCounter

    Halogen-quenched Philips Geiger-Müller liquid-flow counter for beta-radiation measurement. Its construction permits radioactive liquid to pass through the sensitive counting region for continuous or sampled activity measurements.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18511

    ProportionalCounter

    Organic-quenched Philips proportional X-ray counter with a mica side window and xenon filling. Unlike the surrounding Geiger-Müller types, it operates proportionally so pulse amplitude retains information about deposited X-ray energy.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18513

    GeigerMullerCounter

    Self-quenching mica-window Geiger-Müller counter for alpha and beta particles and very-low-energy photons. Its thin window and high-rate design support sensitive counting of weakly penetrating radiation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18514

    GeigerMullerCounter

    Large-area self-quenching mica-window Geiger-Müller counter for alpha and beta particles and low-energy photons. The enlarged sensitive window improves collection efficiency for weakly penetrating radiation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18515

    GeigerMullerCounter

    Low-background halogen-quenched Geiger-Müller beta counter designed for anticoincidence measurement systems, where surrounding guard detection suppresses background events and improves sensitivity to weak beta activity.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18516

    GeigerMullerCounter

    Low-background halogen-quenched Geiger-Müller beta counter intended for use with an anticoincidence guard counter, enabling sensitive beta measurements with reduced cosmic-ray and environmental background.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18517

    GeigerMullerCounter

    Halogen-quenched Geiger-Müller anticoincidence guard counter designed to detect cosmic-ray background events so they can be rejected from simultaneous low-level radiation measurements.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18518

    GeigerMullerCounter

    Halogen-quenched Geiger-Müller anticoincidence guard counter for low-background beta measurements, detecting coincident background events so associated pulses can be rejected from the primary counting channel.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18519

    GeigerMullerCounter

    High-current halogen-quenched Geiger-Müller monitoring counter for gamma and hard X-radiation. Its construction is intended for radiation-monitoring service where comparatively intense penetrating radiation must be counted reliably.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18520

    GeigerMullerCounter

    Halogen-quenched Philips Geiger-Müller counter designed specifically for gamma-radiation measurement, with a stable counting plateau and long-life fill for monitoring and radiation-measurement instrumentation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18523

    GeigerMullerCounter

    Halogen-quenched mica-window Geiger-Müller counter for gamma and beta radiation. Its thin entrance window broadens beta sensitivity while retaining response to penetrating gamma radiation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18524

    GeigerMullerCounter

    Halogen-quenched Geiger-Müller counter designed for gamma and beta measurements of liquid samples. Its sample-containing geometry places radioactive liquid close to the sensitive volume for efficient activity counting.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 1852401

    GeigerMullerCounter

    18524/01 variant of the halogen-quenched Geiger-Müller counter for gamma and beta measurements of liquid samples, using sample-containing geometry for efficient radioactive-liquid activity measurements.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18526

    GeigerMullerCounter

    Halogen-quenched end-window Geiger-Müller counter for alpha, beta, and gamma radiation. Its windowed construction permits detection of penetrating and less-penetrating radiation while permanent gas quenching supports stable counting operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18529

    GeigerMullerCounter

    18529 specialized - radiation counter electronic tube specifications and datasheets.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18533

    GeigerMullerCounter

    Halogen-quenched Geiger-Müller radiation counter.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18536

    GeigerMullerCounter

    Halogen-quenched Geiger-Müller radiation counter.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18537

    GeigerMullerCounter

    18537 specialized - radiation counter electronic tube specifications and datasheets.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18538

    GeigerMullerCounter

    Halogen-quenched Geiger-Müller radiation counter.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18545

    GeigerMullerCounter

    Halogen-quenched Geiger-Müller radiation counter.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18550

    GeigerMullerCounter

    Halogen-quenched thin-wall Geiger-Müller beta/gamma radiation counter.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 18552

    GeigerMullerCounter

    Halogen-quenched beta/gamma Geiger-Müller radiation counter.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 1B102

    GeigerMullerCounter

    Miniature mica-window Geiger-Müller counter designed primarily for beta measurements in laboratory and field instruments. A long self-quenching plateau and windowed construction provide practical sensitivity for portable radiation work.

    Base
    Not recorded
    Socket
    MEDIUM7
    Heater
    Not recorded
    Sections
    1
  • 1B106

    GeigerMullerCounter

    Mica-window Geiger-Müller beta counter designed for reduced operating voltage, high sensitivity, and long counting life. Its windowed construction suits laboratory and field measurement of beta-emitting sources.

    Base
    Not recorded
    Socket
    A182
    Heater
    Not recorded
    Sections
    1
  • 1B124

    GeigerMullerCounter

    Metal Geiger-Müller counter intended for gamma-ray measurement in equipment and well-logging service. Rugged construction and field-oriented application make it suitable for subsurface radiation surveys and related instrumentation.

    Base
    Not recorded
    Socket
    A182
    Heater
    Not recorded
    Sections
    1
  • 1B125

    GeigerMullerCounter

    Metal Geiger-Müller counter for gamma-ray measurement in bore-hole and related field apparatus. Its rugged construction is intended for radiation logging and other measurements performed in demanding inaccessible environments.

    Base
    Not recorded
    Socket
    A182
    Heater
    Not recorded
    Sections
    1
  • 1B126

    GeigerMullerCounter

    Metal Geiger-Müller gamma-ray probing counter for radioactive-tracer work in inaccessible locations. Its specialized construction supports field detection where the sensing tube must operate remotely within confined or difficult environments.

    Base
    Not recorded
    Socket
    A182
    Heater
    Not recorded
    Sections
    1
  • 1B67

    GeigerMullerCounter

    Self-quenching Geiger-Müller counter for beta and gamma radiation detection and measurement. The gas-filled tube provides pulse-counting response for general radiation survey and laboratory instrumentation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 1B68

    GeigerMullerCounter

    Self-quenching Geiger-Müller counter for beta and gamma radiation detection and measurement. Its gas-filled pulse-counting operation suits general radiation survey, monitoring, and laboratory instruments.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 1B69

    GeigerMullerCounter

    Gas-filled Geiger-Müller radiation counter for pulse-counting detection. Available manufacturer material identifies the counter function but does not support a more specific radiation species or application without inference.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 1B71

    GeigerMullerCounter

    Gas-filled Geiger-Müller radiation counter for pulse-counting detection. The available source establishes its counter function but does not provide enough supported detail to assign a narrower radiation-sensitivity description.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1