Specialized tube type
Specialized - Radiation Counter vacuum tubes
Specialized - Radiation Counter records in Tube Tinker cover 119 tube designations, including 211 preserved original datasheets. Compare bases, sockets, heater requirements, construction, exact variations, and directional replacement options.
- Tube records
- 119
- Original datasheets
- 211
- Variation families
- 2
- Tubes with alternatives
- 0
About Specialized - Radiation Counter tubes
If the tube is described as a radiation counter / detector then apply this type.
Electrical range
- Nominal heater voltage
- 0–6.3 V
- Nominal heater current
- 0–1.85 A
Common specialized - radiation counter characteristics
These are the most frequently recorded attributes among tubes in this category.
Bases
- 3PIN1
- 9NX1
Sockets
- A1825
- B41
- B9A1
- IO1
- MEDIUM71
- SUBMINIATURE81
Constructions
- GeigerMullerCounter85
- IonizationChamber14
- ProportionalCounter8
- FissionCounter6
- FissionIonizationDetector2
- Rectifier2
- Other1
- RadiationDetectorOther1
Specialized - Radiation Counter tube list
Page 1 of 3
100C GeigerMullerCounter
Permanent-sensitivity argon-filled Geiger-Müller counter with a thin mica window for beta and X-ray detection. It operates around 1.2 kV and provides a broad counting plateau with approximately 200 µs dead time.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
100CB GeigerMullerCounter
Permanent-sensitivity argon-filled Geiger-Müller counter with a thin mica window for beta and X-ray detection. The based version operates around 1.2 kV with a broad plateau and approximately 200 µs dead time.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
100N GeigerMullerCounter
Neon-filled self-quenching Geiger-Müller counter with a thin mica window for beta detection. It operates around 700 V and provides a broad counting plateau with approximately 200 µs dead time.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
100NB GeigerMullerCounter
Based version of the neon-filled self-quenching Geiger-Müller counter for beta detection, using a thin mica window and broad operating plateau for general radiation-counting instrumentation.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
120C GeigerMullerCounter
Gas-filled Geiger-Müller radiation counter designed for beta and X-ray detection, using a thin mica window and self-quenching fill for stable pulse counting in laboratory radiation instruments.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
120N GeigerMullerCounter
Self-quenching gas-filled Geiger-Müller counter intended for beta-radiation detection, using a thin mica window and stable counting plateau for general laboratory and monitoring applications.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
120NB GeigerMullerCounter
Based self-quenching Geiger-Müller counter intended for beta-radiation detection, combining a thin mica entrance window with gas-filled pulse-counting operation for laboratory radiation measurements.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
153C GeigerMullerCounter
Gas-filled Geiger-Müller radiation counter for particle or photon detection, designed to produce discrete counting pulses over a stable operating plateau in radiation-measurement equipment.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18500 GeigerMullerCounter
Philips self-quenching Geiger-Müller radiation counter intended for ionizing-radiation measurement. Manufacturer data specify counting plateau, background, timing, life, and construction characteristics for laboratory instrumentation.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18501 GeigerMullerCounter
Philips self-quenching Geiger-Müller counter for radiation measurement, with manufacturer specifications covering operating voltage, plateau behavior, background count, dead time, expected life, and detector construction.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18502 GeigerMullerCounter
Philips self-quenching Geiger-Müller radiation counter designed for pulse-counting measurement of ionizing radiation, with published operating plateau, background, timing, lifetime, and construction data.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18503 GeigerMullerCounter
Philips self-quenching Geiger-Müller radiation counter for ionizing-radiation measurement. Its manufacturer data characterize stable counting operation through specified threshold, plateau, background, timing, and detector-life limits.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18504 GeigerMullerCounter
Philips self-quenching Geiger-Müller radiation counter intended for ionizing-radiation measurement, with published characteristics for operating plateau, background count, dead time, expected life, and construction.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18505 GeigerMullerCounter
Self-quenching Philips mica-window Geiger-Müller counter for alpha, beta, and gamma measurement. Its thin window and halogen-quenched gas fill support broad radiation sensitivity with a long operating life.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18506 GeigerMullerCounter
Self-quenching Philips mica-window Geiger-Müller counter for alpha, beta, and gamma measurement. It combines a long operating plateau with halogen quenching and an enlarged sensitive window for radiation counting.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18509 GeigerMullerCounter
Miniature self-quenching Philips Geiger-Müller counter for gamma and high-energy beta radiation. Its compact cathode and low background suit small radiation-monitoring and counting instruments.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
1850902 GeigerMullerCounter
18509/02 miniature self-quenching Geiger-Müller counter for gamma and high-energy beta radiation. This variant provides a short dead time and compact construction for relatively high-rate radiation counting.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18510 GeigerMullerCounter
Halogen-quenched Philips Geiger-Müller liquid-flow counter for beta-radiation measurement. Its construction permits radioactive liquid to pass through the sensitive counting region for continuous or sampled activity measurements.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18511 ProportionalCounter
Organic-quenched Philips proportional X-ray counter with a mica side window and xenon filling. Unlike the surrounding Geiger-Müller types, it operates proportionally so pulse amplitude retains information about deposited X-ray energy.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18513 GeigerMullerCounter
Self-quenching mica-window Geiger-Müller counter for alpha and beta particles and very-low-energy photons. Its thin window and high-rate design support sensitive counting of weakly penetrating radiation.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18514 GeigerMullerCounter
Large-area self-quenching mica-window Geiger-Müller counter for alpha and beta particles and low-energy photons. The enlarged sensitive window improves collection efficiency for weakly penetrating radiation.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18515 GeigerMullerCounter
Low-background halogen-quenched Geiger-Müller beta counter designed for anticoincidence measurement systems, where surrounding guard detection suppresses background events and improves sensitivity to weak beta activity.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18516 GeigerMullerCounter
Low-background halogen-quenched Geiger-Müller beta counter intended for use with an anticoincidence guard counter, enabling sensitive beta measurements with reduced cosmic-ray and environmental background.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18517 GeigerMullerCounter
Halogen-quenched Geiger-Müller anticoincidence guard counter designed to detect cosmic-ray background events so they can be rejected from simultaneous low-level radiation measurements.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18518 GeigerMullerCounter
Halogen-quenched Geiger-Müller anticoincidence guard counter for low-background beta measurements, detecting coincident background events so associated pulses can be rejected from the primary counting channel.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18519 GeigerMullerCounter
High-current halogen-quenched Geiger-Müller monitoring counter for gamma and hard X-radiation. Its construction is intended for radiation-monitoring service where comparatively intense penetrating radiation must be counted reliably.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18520 GeigerMullerCounter
Halogen-quenched Philips Geiger-Müller counter designed specifically for gamma-radiation measurement, with a stable counting plateau and long-life fill for monitoring and radiation-measurement instrumentation.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18523 GeigerMullerCounter
Halogen-quenched mica-window Geiger-Müller counter for gamma and beta radiation. Its thin entrance window broadens beta sensitivity while retaining response to penetrating gamma radiation.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18524 GeigerMullerCounter
Halogen-quenched Geiger-Müller counter designed for gamma and beta measurements of liquid samples. Its sample-containing geometry places radioactive liquid close to the sensitive volume for efficient activity counting.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
1852401 GeigerMullerCounter
18524/01 variant of the halogen-quenched Geiger-Müller counter for gamma and beta measurements of liquid samples, using sample-containing geometry for efficient radioactive-liquid activity measurements.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18526 GeigerMullerCounter
Halogen-quenched end-window Geiger-Müller counter for alpha, beta, and gamma radiation. Its windowed construction permits detection of penetrating and less-penetrating radiation while permanent gas quenching supports stable counting operation.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18529 GeigerMullerCounter
18529 specialized - radiation counter electronic tube specifications and datasheets.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18533 GeigerMullerCounter
Halogen-quenched Geiger-Müller radiation counter.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18536 GeigerMullerCounter
Halogen-quenched Geiger-Müller radiation counter.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18537 GeigerMullerCounter
18537 specialized - radiation counter electronic tube specifications and datasheets.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18538 GeigerMullerCounter
Halogen-quenched Geiger-Müller radiation counter.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18545 GeigerMullerCounter
Halogen-quenched Geiger-Müller radiation counter.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18550 GeigerMullerCounter
Halogen-quenched thin-wall Geiger-Müller beta/gamma radiation counter.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
18552 GeigerMullerCounter
Halogen-quenched beta/gamma Geiger-Müller radiation counter.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
1B102 GeigerMullerCounter
Miniature mica-window Geiger-Müller counter designed primarily for beta measurements in laboratory and field instruments. A long self-quenching plateau and windowed construction provide practical sensitivity for portable radiation work.
- Base
- Not recorded
- Socket
- MEDIUM7
- Heater
- Not recorded
- Sections
- 1
1B106 GeigerMullerCounter
Mica-window Geiger-Müller beta counter designed for reduced operating voltage, high sensitivity, and long counting life. Its windowed construction suits laboratory and field measurement of beta-emitting sources.
- Base
- Not recorded
- Socket
- A182
- Heater
- Not recorded
- Sections
- 1
1B124 GeigerMullerCounter
Metal Geiger-Müller counter intended for gamma-ray measurement in equipment and well-logging service. Rugged construction and field-oriented application make it suitable for subsurface radiation surveys and related instrumentation.
- Base
- Not recorded
- Socket
- A182
- Heater
- Not recorded
- Sections
- 1
1B125 GeigerMullerCounter
Metal Geiger-Müller counter for gamma-ray measurement in bore-hole and related field apparatus. Its rugged construction is intended for radiation logging and other measurements performed in demanding inaccessible environments.
- Base
- Not recorded
- Socket
- A182
- Heater
- Not recorded
- Sections
- 1
1B126 GeigerMullerCounter
Metal Geiger-Müller gamma-ray probing counter for radioactive-tracer work in inaccessible locations. Its specialized construction supports field detection where the sensing tube must operate remotely within confined or difficult environments.
- Base
- Not recorded
- Socket
- A182
- Heater
- Not recorded
- Sections
- 1
1B67 GeigerMullerCounter
Self-quenching Geiger-Müller counter for beta and gamma radiation detection and measurement. The gas-filled tube provides pulse-counting response for general radiation survey and laboratory instrumentation.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
1B68 GeigerMullerCounter
Self-quenching Geiger-Müller counter for beta and gamma radiation detection and measurement. Its gas-filled pulse-counting operation suits general radiation survey, monitoring, and laboratory instruments.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
1B69 GeigerMullerCounter
Gas-filled Geiger-Müller radiation counter for pulse-counting detection. Available manufacturer material identifies the counter function but does not support a more specific radiation species or application without inference.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1
1B71 GeigerMullerCounter
Gas-filled Geiger-Müller radiation counter for pulse-counting detection. The available source establishes its counter function but does not provide enough supported detail to assign a narrower radiation-sensitivity description.
- Base
- Not recorded
- Socket
- Not recorded
- Heater
- Not recorded
- Sections
- 1