Large-area self-quenching mica-window Geiger-Müller counter for alpha and beta particles and low-energy photons. The enlarged sensitive window improves collection efficiency for weakly penetrating radiation.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

18514 — Self-Quenching Radiation Counter Tube

The 18514 is a self-quenching radiation counter tube designed for the detection of alpha particles, beta particles, and photons down to very low energy levels. Filled with a rare gas and featuring a thin mica window, the tube is utilized in laboratory, medical, and industrial tracer techniques, thickness measuring instruments, and general survey or laboratory monitoring equipment.

Mechanical Construction and Protection

The 18514 is constructed with a thin mica window at one end to permit the entry of low-energy ionizing radiation. The physical and mechanical specifications of the tube and its protective housing include:

  • Mica Window Diameter: 27.8 mm
  • Mica Window Area: 605 mm²
  • Mica Window Density: 3.5 to 4 mg/cm² (uniform for each individual counter)
  • Cathode Wall Thickness: 1.2 mm
  • Tube Weight: 56 g (alone), 156 g (with container)
  • Tube Dimensions: Maximum diameter of 30 mm, maximum length of 98 mm
  • Container Dimensions: Maximum diameter of 54 mm, maximum length of 121 mm

The tube is delivered inside a protective aluminium container that is electrically connected to the cathode. For testing or for measuring gamma radiation and high-energy particles, the tube can remain inside this container. The container features a V-groove that can be cut through with a penknife to remove the counter when necessary. Additionally, a detachable rubber cap is supplied to protect the delicate mica window when the tube is not being used to measure low-energy radiation.

Electrical and Operating Characteristics

The electrical behavior of the 18514 is defined by its rare gas filling and physical geometry. The operating parameters under typical conditions are:

ParameterSpecification
Threshold Voltage600 V
Plateau Length300 V (minimum 200 V)
Plateau Slope (at 100 counts/sec)0.06 %/V typical, 0.15 %/V maximum
Dead Time250 to 100 µs (dependent on working voltage)
Maximum Counting Rate6,000 counts/sec
Background (Shielded with 1/4" Al + 2" Pb)Maximum 40 counts/min
Interelectrode Capacitance (Tube alone)1 pF
Interelectrode Capacitance (In container)5 pF

The dead time of the tube varies from 250 µs down to 100 µs depending on the applied working voltage. The background count is kept to a maximum of 40 counts per minute when the tube is shielded by a combination of 1/4-inch aluminium and 2-inch lead shielding.

Environmental and Life Ratings

The 18514 is rated for operation across a wide thermal range and exhibits a long operating life:

  • Ambient Temperature Range: -55 °C to +75 °C
  • Count Life Expectancy: Minimum 10¹⁰ counts

Detection Efficiency

The detection capabilities of the 18514 vary depending on the type of radiation and its incident energy:

  • Gamma and Radium Sensitivity: When exposed to a radium source of 2.39 ± 1% millicurie, the tube produces a counting rate of 7,210 counts per minute for a radiation intensity of 2.5 m röntgen/hour.
  • Beta Particles: The tube detects and counts all beta particles arriving at the mica window with an energy exceeding 50 keV. The actual counting rate is subject to the source type, geometry, and self-absorption factors.
  • Alpha Particles: The stopping power of the mica window is equivalent to 3 cm of air. Alpha particles arriving at the window with an energy of approximately 5 MeV are successfully counted.

Circuit-Specific Operating Example

In a typical application circuit, the 18514 is integrated with an external amplifier stage. The cathode is grounded and connected to the protective aluminium container. The recommended circuit values are as follows:

  • Anode Series Resistor: 2.7 MΩ (connected to the high-voltage HT+ supply)
  • Coupling Capacitor: 300 pF
  • Grid Series Resistor: 330 Ω (connected directly to the grid of the amplifier tube)
  • Grid Leak Resistor: 1 MΩ

Technical Summary

The 18514 is a robust, rare-gas-filled, self-quenching radiation counter tube featuring a 27.8 mm diameter mica window. It is designed to detect alpha, beta, and gamma radiation across a temperature range of -55 °C to +75 °C with a minimum life expectancy of 10¹⁰ counts. Operating with a threshold voltage of 600 V and a plateau length of 300 V, the tube provides reliable radiation measurement capabilities in laboratory, medical, and industrial environments.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

GeigerMullerCounter

X-ray radiationInterelectrode capacitances
Max plate voltage
600 V

Published ratings and characteristics promoted semantically from the approved Philips source.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1957 Philips Receiving and Amplifying Tubes

Published operating points and test conditions from this source.

SECTION 1

GeigerMullerCounter

Characteristic

  • Starting / Threshold Voltage Minimum

    600 V

  • Plateau Length

    300 V

  • Minimum Plateau Length

    200 V

  • Plateau Slope Maximum

    0.15 %/V

    At published counting condition

  • Dead Time Maximum

    250 us

  • Background Count Maximum

    40 counts/min

    Published shielding condition

  • Mica Window Area

    605 mm2

  • Count Life Expectancy Minimum

    10000000000 counts

Other

  • Maximum Counting Rate

    6000 counts/s

  • Maximum Ambient Temperature

    75 C

Data set 02

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

GeigerMullerCounter

Construction

  • Filling

    Rare gas

  • Mica window diameter

    27.8 mm

  • Mica window area

    605 mm2

  • Mica window areal density

    3.5-4 mg/cm2

Capacitance

  • Interelectrode capacitance

    1 pF

Characteristics

  • Plateau length

    300 V

  • Plateau slope typical

    0.06 %/V

    At100CountsPerSecond

  • Plateau slope maximum

    0.15 %/V

    At100CountsPerSecond

  • Dead time minimum

    100 usec

    VoltageDependent

  • Dead time maximum

    250 usec

    VoltageDependent

  • Maximum counting rate

    6000 counts/sec

  • Shielded background maximum

    40 counts/min

    1/4inAl;2inPb

  • Expected count life minimum

    10000000000 counts