Specialized - Radiation Counter ·GeigerMullerCounter

18501

Philips self-quenching Geiger-Müller counter for radiation measurement, with manufacturer specifications covering operating voltage, plateau behavior, background count, dead time, expected life, and detector construction.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

18501 — Non-Self-Quenching Radiation Counter Tube

The 18501 is a non-self-quenching Geiger-Müller radiation counter tube designed for the detection and measurement of beta, gamma, and neutron radiation. Utilizing an argon-hydrogen gas filling, this tube features a robust metal-glass construction with a chromium-iron cathode. Because it is a non-self-quenching design, the 18501 requires external quenching circuitry, such as a Neher-Harper configuration, to terminate the ionization discharge after each detection event.

Construction and Physical Dimensions

The 18501 is constructed as a cylindrical tube with a glass envelope housing a coaxial electrode structure. The cathode is composed of an alloy containing 28% chromium and 72% iron, with an inside diameter of 14.4 mm and an effective active length of 40 mm.

The physical envelope has a maximum overall length of 135 mm and an outer diameter ranging from 16 to 19 mm. Electrical connection to the anode is made via an M4 screw terminal located at the anode end (designated 'a'), while the cathode terminal is located at the opposite end (designated 'k'). The internal capacitance of the tube is exceptionally low, rated at 2 pF.

Operating and Plateau Characteristics

The electrical operation of the 18501 is defined by high-voltage parameters typical of argon-hydrogen filled Geiger-Müller tubes. The tube exhibits a starting voltage of 900 V and operates within a defined voltage range:

ParameterValue
Minimum Operating Voltage1000 V
Typical Operating Voltage1050 V
Maximum Operating Voltage1100 V
Plateau Beginning950 V
Plateau Length150 V
Maximum Plateau Slope0.02% per V

The plateau region begins at 950 V and extends for 150 V, providing a stable operating range where the count rate remains highly independent of small fluctuations in the applied high voltage. The maximum slope of this plateau is extremely flat, restricted to 0.02% per volt.

Performance and Detection Capabilities

When properly shielded and operated within its specified voltage range, the 18501 exhibits high sensitivity and low background noise:

  • Cosmic Ray Efficiency: The tube achieves a cosmic ray detection efficiency of 98.5%.
  • Background Count: When shielded with 2 inches of lead (Pb) and 1/8 inch of aluminum (Al), the background count rate is limited to a maximum of 20 counts per minute.
  • Expected Life: The tube is highly durable, with an expected operating life of 10^10 counts.
  • Dead Time: The inherent dead time of the tube is 75 µs.

Applications and Circuit Integration

The 18501 is designed for measuring beta, gamma, and neutron radiation. For the detection of thermal neutrons, the tube must be wrapped in a cadmium foil of approximately 0.5 mm thickness.

Circuit Requirements

Because the argon-hydrogen fill gas does not provide self-quenching action, the tube must be operated with an external Neher-Harper quenching circuit. This circuit actively lowers the anode voltage below the starting potential immediately after an ionization event, allowing the tube to recover.

The output of the quenching circuit must be connected to an amplifier and scaler system characterized by:

  • An input sensitivity of approximately 0.1 V.
  • A resolving time of less than 5 µs.

Mounting and Maintenance

To preserve the low internal capacitance (2 pF) and prevent parasitic circuit loading, low-capacity mounting is required, and all electrical connections must be kept as short as possible. Additionally, the tube must be kept dry and thoroughly cleaned to prevent surface leakage currents, which could otherwise degrade measurement accuracy or cause spurious counts.

Technical Summary

The 18501 is a cylindrical, non-self-quenching Geiger-Müller radiation counter tube filled with an argon-hydrogen gas mixture. Featuring a 28% chromium and 72% iron cathode with an inside diameter of 14.4 mm, it is optimized for measuring beta, gamma, and neutron radiation. Operating at a typical voltage of 1050 V, it features a 150 V plateau with a maximum slope of 0.02% per volt. Successful operation requires a Neher-Harper quenching circuit, short low-capacity connections, and clean, dry operating conditions to prevent leakage.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

GeigerMullerCounter

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Radiation-counter discharge tube.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1957 Philips Receiving and Amplifying Tubes

Published operating points and test conditions from this source.

SECTION 1

GeigerMullerCounter

Characteristics

  • Starting Voltage

    900 V

  • Operating Voltage

    1050 V

  • Capacitance

    2 pF

  • Plateau Length

    150 V

  • Dead Time

    75 us

  • Cosmic Ray Efficiency

    98.5 percent

Data set 02

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

GeigerMullerCounter

Characteristics

  • Capacitance

    2 pF

    Counter tube

  • Cosmic ray efficiency

    98.5 %

    Published counter efficiency

Other

  • Operating voltage minimum

    1000 V

    Geiger-Muller operation

  • Operating voltage maximum

    1100 V

    Geiger-Muller operation