Skip to main content

Specialized - Radiation Counter ·GeigerMullerCounter

1B125

Metal Geiger-Müller counter for gamma-ray measurement in bore-hole and related field apparatus. Its rugged construction is intended for radiation logging and other measurements performed in demanding inaccessible environments.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
A182
Base pins
-
Nominal heater
-

Description

1B125 — Metal Counter Tube

The 1B125 (also referred to as the 1B125 Thyrode) is a metal Geiger-Müller type counter tube designed for radiation detection and measurement. Characterized by its substantial physical length and brass construction, this tube is engineered for applications requiring high sensitivity and robust environmental tolerance.

Physical Construction and Base Configuration

The 1B125 features a rugged metal envelope with a brass wall thickness of 300 mg/cm². It is a physically large device, possessing an active detection length of 16 inches, a body diameter of 1 inch, and an overall length of 18-1/4 inches.

Electrical connection is established via a standard RMA type A1-82 coaxial tube base, which provides a coaxial connection for the Anode (A) and Cathode (K). The tube is designed to be compatible with specific mounting hardware, including Victoreen socket types 380 and 500, as well as the Victoreen probe type 389.

Electrical Characteristics and Operating Points

For new tubes, the electrical parameters are defined by specific threshold and plateau characteristics:

  • Threshold Voltage: Maximum of 800 Volts.
  • Plateau Length: Minimum of 200 Volts.
  • Plateau Slope: Maximum of 3% per 100 Volts, evaluated over a voltage range (V_0) of 800 to 1000 Volts.
  • Recovery Time: 150 microseconds.
  • Background Count Rate: 300 counts per minute (C/M) when operated at a voltage (V_0) of 900 Volts.

The recommended operating voltage range for the 1B125 is between a minimum of 850 Volts and a maximum of 950 Volts.

Environmental Ratings and Service Life

The 1B125 is rated to operate under demanding environmental conditions, making it suitable for field deployment:

ParameterLimit
Minimum Ambient Temperature-10 °C
Maximum Ambient Temperature100 °C
Maximum Relative Humidity100%

The tube has an expected operating life of 10^9 counts when operated at a count rate of 6000 C/M and a voltage (V_0) of 900 Volts. The end point of its useful life is reached when the plateau slope degrades to 10% per 100 Volts, measured over a voltage range (V_0) of 850 to 950 Volts.

Applications and Parallel Operation

The physical dimensions and electrical properties of the 1B125 make it highly suited for several specialized radiation detection roles:

  • Cosmic Ray Studies: The 16-inch active length provides the large cross-sectional area necessary for cosmic ray research.
  • High-Speed Prospecting: The tube is utilized for searching for radioactive ores from aircraft or fast-moving vehicles, where rapid detection over a wide area is critical.
  • Environmental Monitoring: It is employed to monitor the radioactive content of both air and water.
  • Parallel Cluster Operation: Due to their high electrical uniformity, multiple 1B125 tubes can be operated in parallel in a cluster configuration to significantly increase overall detection sensitivity.

Socket description

RETMA/RMA A1-82 two-contact coaxial radiation-counter tube base family

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
A182
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 0

GeigerMullerCounter

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 Victoreen

Published operating points and test conditions from this source.

SECTION 0

GeigerMullerCounter

Other

  • ThresholdVoltage

    800 V

    Max

  • Operating Voltage

    800 to 900 V

Characteristic

  • PlateauLength

    200 V

    Minimum

  • PlateauSlope

    30 %/100V

    Maximum

  • RecoveryTime

    150 us

  • Background

    100 counts/min

  • ActiveLength

    16 in