- Base
- —
- Socket code
- —
- Sections
- 1
Electronic tube and vacuum tube catalog
Catalog results
- Base
- —
- Socket code
- B13B
- Sections
- 1
B13B - B13B Nixie 13-contact
Cold-cathode Nixie numerical indicator cross-referenced to RFT Z560M, intended for direct glowing digit display in electronic readout equipment.
Source PDFs (1)
- Base
- —
- Socket code
- DUODECAL12
- Sections
- 1
DUODECAL12 - Duodecal 12-contact color CRT base
Gas-filled cold-cathode decade counting tube that transfers a glow through ten positions to count pulses from zero through nine.
- Base
- —
- Socket code
- SK207
- Sections
- 1
- Plate
- 170 V
- Ik max
- 12 mA
SK207 - SK-207 / RTS-44 14-contact Nixie socket family
Ultra-long-life cold-cathode Nixie indicator displaying digits 0–9 and two decimal points for direct electronic numerical readout.
Source PDFs (1)
- Base
- —
- Socket code
- SK207
- Sections
- 1
- Plate
- 170 V
- Ik max
- 12 mA
SK207 - SK-207 / RTS-44 14-contact Nixie socket family
Ultra-long-life cold-cathode Nixie numeral indicator for DC or pulsed operation, displaying digits 0–9 plus two decimal points.
Source PDFs (1)
- Base
- —
- Socket code
- SK207
- Sections
- 1
- Plate
- 170 V
- Ik max
- 12 mA
SK207 - SK-207 / RTS-44 14-contact Nixie socket family
Ultra-long-life 5870-family cold-cathode numerical indicator displaying ten digits and two decimal points for electronic readout systems.
Source PDFs (1)
- Base
- —
- Socket code
- SK207
- Sections
- 1
- Plate
- 170 V
- Ik max
- 12 mA
SK207 - SK-207 / RTS-44 14-contact Nixie socket family
Ultra-long-life 5870-family Nixie indicator for DC or pulsed numerical display, providing digits 0–9 and two decimal points.
Source PDFs (1)
- Base
- —
- Socket code
- SK207
- Sections
- 1
- Plate
- 170 V
- Ik max
- 12 mA
SK207 - SK-207 / RTS-44 14-contact Nixie socket family
Ultra-long-life cold-cathode 5870-family numeral indicator displaying digits 0–9 and two decimal points for direct electronic readout.
Source PDFs (1)
- Base
- —
- Socket code
- B12C
- Sections
- 1
- Ik max
- 0.6 mA
12 pins - B12C - Duodecar 12-contact
Cold-cathode bidirectional decade counter with multiple electrical outputs and direct glow indication of the active counting position.
- Base
- —
- Socket code
- B12A
- Sections
- 1
- Plate
- 800 V
- Ik max
- 0.6 mA
12 pins - B12A - Duodecal 12-contact
Gas-filled cold-cathode decade counter/readout tube with ten output cathodes and top-viewed glow indication.
- Base
- —
- Socket code
- —
- Sections
- 1
- Ik max
- 0.6 mA
8 pins
Cold-cathode bidirectional decade counter with a single output cathode and direct glow indication for counting and frequency-division circuits.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 4 mA
13 pins - B13B - B13B Nixie 13-contact
Cold-cathode ten-digit numerical indicator for direct electronic readout, with manufacturer data corresponding to the improved 6844A/BD-302 design.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 4 mA
- Min/Max I
- 1.5 mA / 3 mA
13 pins - B13B - B13B Nixie 13-contact
Gas-filled cold-cathode ten-digit Nixie indicator with common anode and suppressor screen for direct numerical display.
Source PDFs (7)
- Base
- —
- Socket code
- B7G
- Sections
- 1
7 pins - B7G - Miniature 7-contact
Cold-cathode glow-transfer counter tube designed for electronic counting and frequency division rather than passive numerical display alone.
- Base
- —
- Socket code
- SK116
- Sections
- 1
- Ik max
- 2 mA
- Min/Max I
- 0.7 mA / 1.2 mA
SK116 - SK-116 11-contact miniature Nixie socket family
Gas-filled cold-cathode Nixie numerical/readout tube for direct digit indication in electronic instruments and counting equipment.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 5 mA
- Min/Max I
- 2 mA / 3 mA
13 pins - B13B - B13B Nixie 13-contact
Gas-filled cold-cathode Nixie numerical/readout device using a comparatively high striking and operating supply for direct digit display.
- Base
- —
- Socket code
- SK116
- Sections
- 1
- Ik max
- 1.5 mA
SK116 - SK-116 11-contact miniature Nixie socket family
Ultra-long-life miniature gas-filled cold-cathode Nixie numerical indicator designed for compact electronic readout equipment.
- Base
- —
- Socket code
- SK116
- Sections
- 1
- Ik max
- 2 mA
SK116 - SK-116 11-contact miniature Nixie socket family
Ultra-long-life miniature Nixie numerical indicator optimized for reliable direct digit display in low-light or dark environments.
- Base
- —
- Socket code
- —
- Sections
- 1
- Ik max
- 0.6 mA
Cold-cathode gas-filled bidirectional ring-stepping decade counter with visible neon-glow indication of the active count position.
- Base
- —
- Socket code
- B13B
- Sections
- 1
B13B - B13B Nixie 13-contact
Cold-cathode Nixie numerical indicator cross-referenced to RFT Z560M, intended for direct glowing digit display.
Source PDFs (1)
- Base
- CONNECTIONS
- Socket code
- BUTTON13
- Sections
- 1
- Ik max
- 0.8 mA
13 pins - BUTTON13 - 13-contact button base
Cold-cathode decade counting and indicating tube with top-viewed numerical readout and ten separately available output cathodes.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 3 mA
B13B - B13B Nixie 13-contact
Ultra-long-life standard-size gas-filled cold-cathode Nixie numerical indicator for dependable direct electronic readout.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 3.5 mA
B13B - B13B Nixie 13-contact
Cold-cathode Nixie indicator cross-referenced to RFT Z560M, intended for direct numerical or character display in electronic equipment.
- Base
- —
- Socket code
- SK136
- Sections
- 1
- Ik max
- 3.5 mA
SK136 - SK-136 13-contact oval Nixie socket family
Ultra-long-life rectangular gas-filled cold-cathode Nixie numerical indicator for direct electronic digit display.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 4.5 mA
B13B - B13B Nixie 13-contact
Super-size gas-filled cold-cathode Nixie numerical indicator designed for large, highly visible electronic readouts.
- Base
- Special 13-pin
- Socket code
- B13B
- Sections
- 1
- Min/Max I
- 250 mA / 525 mA
13 pins - B13B - B13B Nixie 13-contact
Gas-filled cold-cathode decade counting, switching, and display tube for forward and reverse counting with ten separately brought-out cathodes.
- Base
- —
- Socket code
- —
- Sections
- 1
- Ik max
- 6 mA
- Regulator
- 84 V
Long-life neon-filled cold-cathode top-view numerical indicator displaying digits 0–9 for direct electronic readout.
- Base
- —
- Socket code
- —
- Sections
- 1
Miniature cold-cathode numerical indicator with common anode and ten numeral-shaped cathodes, designed for low-voltage 120 V DC direct readout.
- Base
- —
- Socket code
- B13B
- Sections
- 1
B13B - B13B Nixie 13-contact
Gas-filled cold-cathode Burroughs Nixie numerical/readout device for direct electronic digit indication.
Source PDFs (1)
- Base
- —
- Socket code
- —
- Sections
- 1
Russian two-pulse cold-cathode Dekatron for counting, switching, and counting-calculating equipment, transferring an orange-red glow among successive cathodes.
Source PDFs (1)
- Base
- —
- Socket code
- —
- Sections
- 1
Russian two-pulse cold-cathode Dekatron for electronic counting and switching, using visible glow transfer among cathodes to indicate count position.
Source PDFs (1)
- Base
- —
- Socket code
- RSH30
- Sections
- 1
RSH30 - Soviet RSh30 13-pin display/counting tube base family
Cold-cathode glow-discharge Dekatron for counting, switching, and counting/calculating equipment. Operation transfers a visible violet-blue discharge between cathodes, providing both an electronic counting or switching function and a directly visible indication of the discharge position.
Source PDFs (1)
- Base
- Philips 4-pin
- Socket code
- RSH30
- Sections
- 1
- Plate
- 100 V
- rP
- 15,000 Ω
- gm
- 0.4 mA/V
- μ
- 6
4 pins - RSH30 - Soviet RSh30 13-pin display/counting tube base family
Cold-cathode glow-discharge Dekatron intended for counting, switching, and counting/calculating equipment. A blue visible glow transfers between cathodes as the device advances, combining electronic counting or commutation with direct visual indication.
- Base
- —
- Socket code
- RSH30
- Sections
- 1
RSH30 - Soviet RSh30 13-pin display/counting tube base family
Cold-cathode glow-discharge Dekatron for counting, switching, and counting/calculating equipment. It advances a blue visible discharge among its cathodes, allowing the tube to perform sequential counting or switching while displaying the active position.
Source PDFs (1)
- Base
- —
- Socket code
- —
- Sections
- 1
Cold-cathode glow-discharge Dekatron designed for counting, switching, and counting/calculating equipment. Its violet-blue glow transfers from cathode to cathode, providing sequential electrical operation together with a visible indication of the current state.
Source PDFs (1)
- Base
- Philips 4-pin
- Socket code
- —
- Sections
- 1
- Plate
- 120 V
- rP
- 22,500 Ω
- gm
- 0.4 mA/V
- μ
- 9
4 pins
Cold-cathode glow-discharge Dekatron intended for counting, switching, and counting/calculating equipment. The blue discharge moves sequentially between cathodes, serving as both the active switching/counting mechanism and a visible state indicator.
- Base
- —
- Socket code
- —
- Sections
- 1
Cold-cathode glow-discharge Dekatron for counting, switching, and counting/calculating equipment. It transfers a visible blue glow between successive cathodes, providing sequential counting or switching operation with direct visual indication.
Source PDFs (1)
- Base
- —
- Socket code
- SK116
- Sections
- 1
- Ik max
- 2 mA
- Min/Max I
- 0.7 mA / 1.2 mA
SK116 - SK-116 11-contact miniature Nixie socket family
Miniature gas-filled cold-cathode Nixie numerical readout tube. Burroughs data specify a 120 V maximum ionization voltage and 120 V recommended minimum supply, with operation through an external series current-limiting resistor.
- Base
- —
- Socket code
- SK116
- Sections
- 1
- Ik max
- 2 mA
- Min/Max I
- 0.7 mA / 1.2 mA
SK116 - SK-116 11-contact miniature Nixie socket family
Miniature gas-filled cold-cathode Nixie numerical readout tube. Burroughs data specify a 170 V maximum ionization voltage and 170 V recommended minimum supply, with documented operating circuits for several supply voltages.
- Base
- —
- Socket code
- SK116
- Sections
- 1
- Ik max
- 2 mA
- Min/Max I
- 0.7 mA / 1.2 mA
SK116 - SK-116 11-contact miniature Nixie socket family
Miniature gas-filled cold-cathode Nixie numerical readout tube in the B4021 electrical family. Manufacturer data specify a 120 V maximum ionization voltage and recommended minimum supply, using external series resistance for current limiting.
- Base
- —
- Socket code
- SK116
- Sections
- 1
- Ik max
- 1.5 mA
- Min/Max I
- 0.6 mA / 1.2 mA
SK116 - SK-116 11-contact miniature Nixie socket family
Miniature gas-filled cold-cathode Nixie numerical readout tube in the B4032 electrical family. Burroughs specifies a 170 V maximum ionization voltage and recommended minimum supply, with external resistance controlling operating current.
- Base
- Refer to variations
- Socket code
- SK116
- Sections
- 1
- Ik max
- 1.5 mA
- Min/Max I
- 0.6 mA / 1.2 mA
SK116 - SK-116 11-contact miniature Nixie socket family
Miniature gas-filled cold-cathode Nixie numerical readout tube. Burroughs data specify a 170 V maximum ionization voltage and 170 V recommended minimum supply, with operating conditions also documented for higher anode supplies.
- Base
- —
- Socket code
- —
- Sections
- 1
- Ik max
- 2 mA
Ultra-long-life miniature gas-filled cold-cathode Nixie numerical indicator intended for low-light or dark environments. Its specialized long-life construction distinguishes it from standard miniature numerical readout tubes.
Source PDFs (0)
No source PDFs available.
- Base
- —
- Socket code
- SK116
- Sections
- 1
- Ik max
- 2.5 mA
SK116 - SK-116 11-contact miniature Nixie socket family
Rectangular miniature cold-cathode Nixie indicator documented by Burroughs in its miniature and standard Nixie comparison material. It is a compact glow-discharge readout device intended for visible indication rather than amplification or switching.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 4 mA
- Min/Max I
- 1.5 mA / 3 mA
B13B - B13B Nixie 13-contact
Standard-size gas-filled cold-cathode Nixie numerical readout tube in the 6844A electrical family. Burroughs specifies a 170 V maximum ionization voltage and recommended minimum supply, with operating circuits extending to higher supply voltages.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 4 mA
- Min/Max I
- 1.5 mA / 3 mA
B13B - B13B Nixie 13-contact
Standard-size gas-filled cold-cathode Nixie numerical readout tube in the 6844A electrical family. Manufacturer data specify a 170 V maximum ionization voltage and recommended minimum supply with external series-resistor current control.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 4 mA
- Min/Max I
- 1.5 mA / 3 mA
B13B - B13B Nixie 13-contact
Standard-size gas-filled cold-cathode Nixie numerical readout tube in the 6844A electrical family. Burroughs documentation gives a 170 V maximum ionization voltage and recommended minimum supply, plus operating conditions at higher supply voltages.
- Base
- 9-12 TGL 11608
- Socket code
- B9A
- Sections
- 1
B9A - Small-button Noval 9-contact
Cold-cathode numeric or character indicator cross-referenced in German comparison data to RFT Z8700M. The source explicitly cautions that comparable types need not be electrically identical, so the comparison establishes function without proving exact RFT ratings.
Source PDFs (1)
- Base
- Refer to variations
- Socket code
- B13B
- Sections
- 1
- Ik max
- 3 mA
- Min/Max I
- 1 mA / 2.5 mA
B13B - B13B Nixie 13-contact
Standard-size gas-filled cold-cathode Nixie numerical readout tube. Burroughs data specify a 170 V maximum ionization voltage and recommended minimum supply, with series-resistor operating circuits documented for 170, 250, and 300 V supplies.
- Base
- —
- Socket code
- B13B
- Sections
- 1
- Ik max
- 3.5 mA
- Min/Max I
- 1 mA / 2.5 mA
B13B - B13B Nixie 13-contact
Standard-size gas-filled cold-cathode Nixie numerical readout tube in the B5031 electrical family. Manufacturer data specify a 170 V maximum ionization voltage and recommended minimum supply, with external resistance limiting discharge current.
| Expand sections | More | Electrical Summary | General Summary | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NixieCounterSelectorSwitchCold cathode | - | - | |||||||||||
| NixieNixieCold cathode | - | B13B - B13B Nixie 13-contact Cold-cathode Nixie numerical indicator cross-referenced to RFT Z560M, intended for direct glowing digit display in electronic readout equipment. | |||||||||||
| NixieNixieCold cathode | - | DUODECAL12 - Duodecal 12-contact color CRT base Gas-filled cold-cathode decade counting tube that transfers a glow through ten positions to count pulses from zero through nine. | |||||||||||
| NixieNixieCold cathode |
| SK207 - SK-207 / RTS-44 14-contact Nixie socket family Ultra-long-life cold-cathode Nixie indicator displaying digits 0–9 and two decimal points for direct electronic numerical readout. | |||||||||||
| NixieNixieCold cathode |
| SK207 - SK-207 / RTS-44 14-contact Nixie socket family Ultra-long-life cold-cathode Nixie numeral indicator for DC or pulsed operation, displaying digits 0–9 plus two decimal points. | |||||||||||
| NixieNixieCold cathode |
| SK207 - SK-207 / RTS-44 14-contact Nixie socket family Ultra-long-life 5870-family cold-cathode numerical indicator displaying ten digits and two decimal points for electronic readout systems. | |||||||||||
| NixieNixieCold cathode |
| SK207 - SK-207 / RTS-44 14-contact Nixie socket family Ultra-long-life 5870-family Nixie indicator for DC or pulsed numerical display, providing digits 0–9 and two decimal points. | |||||||||||
| NixieNixieCold cathode |
| SK207 - SK-207 / RTS-44 14-contact Nixie socket family Ultra-long-life cold-cathode 5870-family numeral indicator displaying digits 0–9 and two decimal points for direct electronic readout. | |||||||||||
| NixieNixieCold cathode |
| 12 pins - B12C - Duodecar 12-contact Cold-cathode bidirectional decade counter with multiple electrical outputs and direct glow indication of the active counting position. | |||||||||||
| NixieNixieCold cathode |
| 12 pins - B12A - Duodecal 12-contact Gas-filled cold-cathode decade counter/readout tube with ten output cathodes and top-viewed glow indication. | |||||||||||
| NixieNixieCold cathode |
| 8 pins Cold-cathode bidirectional decade counter with a single output cathode and direct glow indication for counting and frequency-division circuits. | |||||||||||
| NixieNixieCold cathode |
| 13 pins - B13B - B13B Nixie 13-contact Cold-cathode ten-digit numerical indicator for direct electronic readout, with manufacturer data corresponding to the improved 6844A/BD-302 design. | |||||||||||
| NixieNixieCold cathode |
| 13 pins - B13B - B13B Nixie 13-contact Gas-filled cold-cathode ten-digit Nixie indicator with common anode and suppressor screen for direct numerical display. | |||||||||||
| NixieNixieCold cathode | - | 7 pins - B7G - Miniature 7-contact Cold-cathode glow-transfer counter tube designed for electronic counting and frequency division rather than passive numerical display alone. | |||||||||||
| NixieNixieCold cathode |
| SK116 - SK-116 11-contact miniature Nixie socket family Gas-filled cold-cathode Nixie numerical/readout tube for direct digit indication in electronic instruments and counting equipment. | |||||||||||
| NixieNixieCold cathode |
| 13 pins - B13B - B13B Nixie 13-contact Gas-filled cold-cathode Nixie numerical/readout device using a comparatively high striking and operating supply for direct digit display. | |||||||||||
| NixieNixieCold cathode |
| SK116 - SK-116 11-contact miniature Nixie socket family Ultra-long-life miniature gas-filled cold-cathode Nixie numerical indicator designed for compact electronic readout equipment. | |||||||||||
| NixieNixieCold cathode |
| SK116 - SK-116 11-contact miniature Nixie socket family Ultra-long-life miniature Nixie numerical indicator optimized for reliable direct digit display in low-light or dark environments. | |||||||||||
| NixieNixieCold cathode |
| Cold-cathode gas-filled bidirectional ring-stepping decade counter with visible neon-glow indication of the active count position. | |||||||||||
| NixieNixieCold cathode | - | B13B - B13B Nixie 13-contact Cold-cathode Nixie numerical indicator cross-referenced to RFT Z560M, intended for direct glowing digit display. | |||||||||||
| NixieNixieCold cathode |
| 13 pins - BUTTON13 - 13-contact button base Cold-cathode decade counting and indicating tube with top-viewed numerical readout and ten separately available output cathodes. | |||||||||||
| NixieNixieCold cathode |
| B13B - B13B Nixie 13-contact Ultra-long-life standard-size gas-filled cold-cathode Nixie numerical indicator for dependable direct electronic readout. | |||||||||||
| NixieNixieCold cathode |
| B13B - B13B Nixie 13-contact Cold-cathode Nixie indicator cross-referenced to RFT Z560M, intended for direct numerical or character display in electronic equipment. | |||||||||||
| NixieNixieCold cathode |
| SK136 - SK-136 13-contact oval Nixie socket family Ultra-long-life rectangular gas-filled cold-cathode Nixie numerical indicator for direct electronic digit display. | |||||||||||
| NixieNixieCold cathode |
| B13B - B13B Nixie 13-contact Super-size gas-filled cold-cathode Nixie numerical indicator designed for large, highly visible electronic readouts. | |||||||||||
| NixieNixieCold cathode |
| 13 pins - B13B - B13B Nixie 13-contact Gas-filled cold-cathode decade counting, switching, and display tube for forward and reverse counting with ten separately brought-out cathodes. | |||||||||||
| NixieNixieCold cathode |
| Long-life neon-filled cold-cathode top-view numerical indicator displaying digits 0–9 for direct electronic readout. | |||||||||||
| NixieNixieCold cathode | - | Miniature cold-cathode numerical indicator with common anode and ten numeral-shaped cathodes, designed for low-voltage 120 V DC direct readout. | |||||||||||
| NixieNixieCold cathode | - | B13B - B13B Nixie 13-contact Gas-filled cold-cathode Burroughs Nixie numerical/readout device for direct electronic digit indication. | |||||||||||
| NixieNixieCold cathode | - | Russian two-pulse cold-cathode Dekatron for counting, switching, and counting-calculating equipment, transferring an orange-red glow among successive cathodes. | |||||||||||
| NixieNixieCold cathode | - | Russian two-pulse cold-cathode Dekatron for electronic counting and switching, using visible glow transfer among cathodes to indicate count position. | |||||||||||
| NixieNixieCold cathode | - | RSH30 - Soviet RSh30 13-pin display/counting tube base family Cold-cathode glow-discharge Dekatron for counting, switching, and counting/calculating equipment. Operation transfers a visible violet-blue discharge between cathodes, providing both an electronic counting or switching function and a directly visible indication of the discharge position. | |||||||||||
| NixieTriodeCold cathode |
| 4 pins - RSH30 - Soviet RSh30 13-pin display/counting tube base family Cold-cathode glow-discharge Dekatron intended for counting, switching, and counting/calculating equipment. A blue visible glow transfers between cathodes as the device advances, combining electronic counting or commutation with direct visual indication. | |||||||||||
| NixieNixieCold cathode | - | RSH30 - Soviet RSh30 13-pin display/counting tube base family Cold-cathode glow-discharge Dekatron for counting, switching, and counting/calculating equipment. It advances a blue visible discharge among its cathodes, allowing the tube to perform sequential counting or switching while displaying the active position. | |||||||||||
| NixieNixieCold cathode | - | Cold-cathode glow-discharge Dekatron designed for counting, switching, and counting/calculating equipment. Its violet-blue glow transfers from cathode to cathode, providing sequential electrical operation together with a visible indication of the current state. | |||||||||||
| NixieTriodeCold cathode |
| 4 pins Cold-cathode glow-discharge Dekatron intended for counting, switching, and counting/calculating equipment. The blue discharge moves sequentially between cathodes, serving as both the active switching/counting mechanism and a visible state indicator. | |||||||||||
| NixieNixieCold cathode | - | Cold-cathode glow-discharge Dekatron for counting, switching, and counting/calculating equipment. It transfers a visible blue glow between successive cathodes, providing sequential counting or switching operation with direct visual indication. | |||||||||||
| NixieNixieCold cathode |
| SK116 - SK-116 11-contact miniature Nixie socket family Miniature gas-filled cold-cathode Nixie numerical readout tube. Burroughs data specify a 120 V maximum ionization voltage and 120 V recommended minimum supply, with operation through an external series current-limiting resistor. | |||||||||||
| NixieNixieCold cathode |
| SK116 - SK-116 11-contact miniature Nixie socket family Miniature gas-filled cold-cathode Nixie numerical readout tube. Burroughs data specify a 170 V maximum ionization voltage and 170 V recommended minimum supply, with documented operating circuits for several supply voltages. | |||||||||||
| NixieNixieCold cathode |
| SK116 - SK-116 11-contact miniature Nixie socket family Miniature gas-filled cold-cathode Nixie numerical readout tube in the B4021 electrical family. Manufacturer data specify a 120 V maximum ionization voltage and recommended minimum supply, using external series resistance for current limiting. | |||||||||||
| NixieNixieCold cathode |
| SK116 - SK-116 11-contact miniature Nixie socket family Miniature gas-filled cold-cathode Nixie numerical readout tube in the B4032 electrical family. Burroughs specifies a 170 V maximum ionization voltage and recommended minimum supply, with external resistance controlling operating current. | |||||||||||
| NixieNixieCold cathode |
| SK116 - SK-116 11-contact miniature Nixie socket family Miniature gas-filled cold-cathode Nixie numerical readout tube. Burroughs data specify a 170 V maximum ionization voltage and 170 V recommended minimum supply, with operating conditions also documented for higher anode supplies. | |||||||||||
| NixieNixieCold cathode |
| Ultra-long-life miniature gas-filled cold-cathode Nixie numerical indicator intended for low-light or dark environments. Its specialized long-life construction distinguishes it from standard miniature numerical readout tubes. | |||||||||||
| NixieNixieCold cathode |
| SK116 - SK-116 11-contact miniature Nixie socket family Rectangular miniature cold-cathode Nixie indicator documented by Burroughs in its miniature and standard Nixie comparison material. It is a compact glow-discharge readout device intended for visible indication rather than amplification or switching. | |||||||||||
| NixieNixieCold cathode |
| B13B - B13B Nixie 13-contact Standard-size gas-filled cold-cathode Nixie numerical readout tube in the 6844A electrical family. Burroughs specifies a 170 V maximum ionization voltage and recommended minimum supply, with operating circuits extending to higher supply voltages. | |||||||||||
| NixieNixieCold cathode |
| B13B - B13B Nixie 13-contact Standard-size gas-filled cold-cathode Nixie numerical readout tube in the 6844A electrical family. Manufacturer data specify a 170 V maximum ionization voltage and recommended minimum supply with external series-resistor current control. | |||||||||||
| NixieNixieCold cathode |
| B13B - B13B Nixie 13-contact Standard-size gas-filled cold-cathode Nixie numerical readout tube in the 6844A electrical family. Burroughs documentation gives a 170 V maximum ionization voltage and recommended minimum supply, plus operating conditions at higher supply voltages. | |||||||||||
| NixieNixieCold cathode | - | B9A - Small-button Noval 9-contact Cold-cathode numeric or character indicator cross-referenced in German comparison data to RFT Z8700M. The source explicitly cautions that comparable types need not be electrically identical, so the comparison establishes function without proving exact RFT ratings. | |||||||||||
| NixieNixieCold cathode |
| B13B - B13B Nixie 13-contact Standard-size gas-filled cold-cathode Nixie numerical readout tube. Burroughs data specify a 170 V maximum ionization voltage and recommended minimum supply, with series-resistor operating circuits documented for 170, 250, and 300 V supplies. | |||||||||||
| NixieNixieCold cathode |
| B13B - B13B Nixie 13-contact Standard-size gas-filled cold-cathode Nixie numerical readout tube in the B5031 electrical family. Manufacturer data specify a 170 V maximum ionization voltage and recommended minimum supply, with external resistance limiting discharge current. |
