Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Nixie
Other
Input frequency maximum
50 kpps
Nixie ·Nixie
Cold-cathode decade counting and indicating tube with top-viewed numerical readout and ten separately available output cathodes.
Cold-cathode decade counting and indicating tube with top-viewed numerical readout and output cathodes 0 through 9.
13-contact button base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Cold-cathode counter tube; count-rate data retained as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Input frequency maximum
50 kpps
Data set 02
Published operating points and test conditions from this source.
Maximum plate/anode voltage
900 V
Published maximum plate/anode voltage
Transfer voltage
140 V
Transfer voltage .... 140 Volts
(Each pulse)3
-70 V
(Each pulse)3 ............... -70 Volts Min.
Forced Reset pulse Amplitude
-120 V
Forced Reset pulse Amplitude .......... -120 Volts Min.
Cathode Load Resistor4
50 kohm
Cathode Load Resistor4 ............. 50 K-Ohms Max.