Data set 01
1971 Nixie RFT
Published operating points and test conditions from this source.
Nixie
Other
Comparable RFT Type
Z560M
Catalog cross-reference; comparable types are not guaranteed identical
Minimum Operating Supply Voltage
170 V
Published for comparable RFT type Z560M
Cathode Current Minimum
1 mA
Published for comparable RFT type Z560M
Cathode Current Maximum
2.5 mA
Published for comparable RFT type Z560M
Peak Cathode Current
10 mA
Published for comparable RFT type Z560M
Ambient Temperature Minimum
-50 °C
Published for comparable RFT type Z560M
Ambient Temperature Maximum
70 °C
Published for comparable RFT type Z560M
Symbol Height
15.5 mm
Published for comparable RFT type Z560M
Maximum Viewing Distance
10 m
Published for comparable RFT type Z560M
Maximum Bulb Height
26.5 mm
Published for comparable RFT type Z560M
Maximum Bulb Diameter
30.1 mm
Published for comparable RFT type Z560M
Characteristic
Anode Striking Voltage
145 V
Published for comparable RFT type Z560M
Anode Maintaining Voltage
135 V
Published for comparable RFT type Z560M
Anode Extinction Voltage
120 V
Published for comparable RFT type Z560M