Data set 01
1963 Mullard
Published operating points and test conditions from this source.
Nixie
Other
Recommended Anode Supply Voltage
475 V
Recommended Anode Resistor
820000 ohm
Nominal Anode Current
340 uA
Guide Bias Supply Voltage
40 V
Positive
Guide Pulse Amplitude
100 V
Maximum Supply Voltage
550 V
Maximum Cathode Current
525 uA
Maximum Counting Rate
50 kHz
Characteristics
Minimum Supply Voltage
375 V
Nominal Maintaining Voltage
195 V
VaSupply=475V; Ra=820k
Minimum Cathode Current
250 uA
Minimum Time Between Input Pulses
200 us
Minimum Discharge Period
60 us
EachGuideOrMainCathode