- Base
- —
- Socket code
- —
- Electrical Summary
- -
- Sections
- 1
Contact-type vacuum thermocouple with heater wire joined directly to the thermojunction. It converts electrical current into a small thermoelectric voltage for precision current measurement.
Contact-type vacuum thermocouple with heater wire joined directly to the thermojunction. It converts electrical current into a small thermoelectric voltage for precision current measurement.
9 pins
Omegatron mass-spectrometer sensing tube with platinum electrodes and tungsten cathode. It analyzes residual gases by separating ions according to mass-to-charge ratio and measuring partial pressures.
Convectron vertical-reference sensor using heated filaments and gas convection to detect tilt electronically. Two units can form an orthogonal bridge system for precision inclination measurement.
| Heater | 6.3 V / 127 mA |
|---|---|
| Plate | 17 V |
| Ik max | 12 mA |
| rP | 2,000 Ω |
Russian mechanotron transducer using a movable electrode to measure excess pressure electrically. Mechanical pressure displacement changes electrode current for precision instrumentation.
| Heater | 6.3 V / 127 mA |
|---|---|
| Plate | 17 V |
| Ik max | 12 mA |
| rP | 8,000 Ω |
Russian mechanotron pressure transducer for precision excess-pressure measurement. Mechanical movement of an internal electrode produces a corresponding electrical-current change.
| Heater | 6.3 V / 410 mA |
|---|---|
| rP | 1,500 Ω |
Russian mechanotron transducer for measuring angular displacement in a vertical plane. Internal mechanical movement produces an electrical output proportional to angle.
| Heater | 6.3 V / 200 mA |
|---|---|
| Plate | 15 V |
| Ik max | 12 mA |
| rP | 1,900 Ω |
Russian movable-anode mechanotron for precision linear displacement and force measurement. Mechanical motion directly modulates electrode current, providing sensitive electrical readout.
| Heater | 6.3 V / 170 mA |
|---|---|
| Ik max | 10 mA |
| rP | 1,500 Ω |
IO - International Octal
Russian dual movable-anode mechanotron for precision displacement and force measurement. Its differential mechanical-to-electrical conversion provides high sensitivity and long service life.
| Heater | 6.3 V / 200 mA |
|---|---|
| Plate | 20 V |
| Ik max | 12 mA |
| rP | 1,200 Ω |
IO - International Octal
Russian single movable-anode mechanotron for precision linear displacement and force measurement. Mechanical motion produces a sensitive proportional change in electrode current.
| Heater | 6.3 V / 410 mA |
|---|---|
| Ik max | 80 mA |
| rP | 500 Ω |
IO - International Octal
Russian dual movable-anode mechanotron for precision displacement and force measurement. Its differential electrode system provides high mechanical-to-electrical sensitivity.
| Heater | 6.3 V / 410 mA |
|---|---|
| Plate | 20 V |
| Ik max | 13 mA |
| rP | 2,000 Ω |
IO - International Octal
Russian dual movable-anode mechanotron for precision linear displacement and force measurement. It provides especially high current sensitivity to very small mechanical movement.
| Heater | 6.3 V / 410 mA |
|---|---|
| Plate | 30 V |
| Ik max | 6 mA |
| rP | 5,000 Ω |
IO - International Octal
Russian dual movable-anode mechanotron for precision displacement and force measurement. Its differential construction converts small mechanical movement into a sensitive electrical-current change.
| Heater | 6.3 V / 170 mA |
|---|---|
| Plate | 17 V |
| rP | 2,000 Ω |
Russian precision mechanotron displacement and force transducer with high sensitivity, low drift, and long rated service life. Mechanical movement directly modulates electrode current.
Electrochemical mercury coulometer for measuring electric charge or elapsed operating time. Electrochemical transfer of mercury displaces a visible electrolyte index proportional to accumulated charge.
| Heater | 1.15 V |
|---|
8 pins
Omegatron mass-spectrometer sensing tube for residual-gas analysis. Crossed electric and magnetic fields separate ions by mass-to-charge ratio for vacuum-system composition measurement.
8 pins
Calibrated SY1301 Omegatron mass-spectrometer tube for quantitative residual-gas analysis. A tungsten emitter and crossed electric and magnetic fields permit measurement of individual gas partial pressures.
Disc-seal UHF thermocouple for monitoring RF power in resonators, waveguides, and coaxial lines from approximately 300 MHz to 6 GHz.
Disc-seal UHF thermocouple for monitoring microwave power in resonators, waveguides, and coaxial transmission lines from roughly 300 MHz to 6 GHz.
No source PDFs available.
Subminiature vacuum thermocouple current sensor for low-current instrumentation. Electrical current heats an internal element and produces a small thermoelectric voltage proportional to current.
Subminiature vacuum thermocouple current sensor for moderate low-current measurement. Heater current produces a small thermoelectric voltage proportional to electrical input.
Vacuum thermocouple current-measuring device for moderate currents. Electrical heating generates a small thermoelectric voltage used for current indication and instrumentation.
Subminiature vacuum thermocouple current sensor for currents up to several hundred milliamperes. Heater current produces a proportional millivolt-level thermoelectric output.
Indirectly heated subminiature vacuum thermocouple for low-current electrical measurement. Thermal coupling converts heater current into a small thermoelectric instrumentation signal.
Indirectly heated subminiature vacuum thermocouple for moderate low-current measurement. Heater current is converted into a small thermoelectric output voltage.
No source PDFs available.
Indirectly heated subminiature vacuum thermocouple for currents up to several hundred milliamperes. Thermal conversion provides a millivolt-level measurement signal.
No source PDFs available.
Indirectly heated subminiature vacuum thermocouple for very low-current measurement. It converts electrical heating into a small thermoelectric voltage for precision instrumentation.
No source PDFs available.
Indirectly heated subminiature vacuum thermocouple for moderate low-current measurement. Heater current produces a small thermoelectric voltage suitable for instrumentation.
No source PDFs available.
Indirectly heated subminiature vacuum thermocouple for currents up to several hundred milliamperes. It produces a small thermoelectric output proportional to electrical heating.
No source PDFs available.
Argon-filled Bendix Y-type DC Convectron vertical-reference sensor. Gas convection around heated elements produces an electrical indication of inclination for precision attitude measurement.
Bendix DC Convectron vertical-reference sensor using gas convection around a heated filament to provide an electrical indication of tilt. The approximately 400 °C filament establishes the thermal convection pattern whose displacement with inclination produces the sensing signal.
| Expand sections | More | Electrical Summary | General Summary | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4001Specialized | Specialized - Sensor TubeSensor | - | Contact-type vacuum thermocouple with heater wire joined directly to the thermojunction. It converts electrical current into a small thermoelectric voltage for precision current measurement. | ||||||||||
56006Specialized | Specialized - Sensor TubeSensor | - | 9 pins Omegatron mass-spectrometer sensing tube with platinum electrodes and tungsten cathode. It analyzes residual gases by separating ions according to mass-to-charge ratio and measuring partial pressures. | ||||||||||
6361Specialized | Specialized - Sensor TubeSensor | - | Convectron vertical-reference sensor using heated filaments and gas convection to detect tilt electronically. Two units can form an orthogonal bridge system for precision inclination measurement. | ||||||||||
6MDX1BSpecialized | Specialized - Sensor TubeSensor |
| Russian mechanotron transducer using a movable electrode to measure excess pressure electrically. Mechanical pressure displacement changes electrode current for precision instrumentation. | ||||||||||
6MDX3BSpecialized | Specialized - Sensor TubeSensor |
| Russian mechanotron pressure transducer for precision excess-pressure measurement. Mechanical movement of an internal electrode produces a corresponding electrical-current change. | ||||||||||
6MUX6PSpecialized | Specialized - Sensor TubeSensor |
| Russian mechanotron transducer for measuring angular displacement in a vertical plane. Internal mechanical movement produces an electrical output proportional to angle. | ||||||||||
6MX1BSpecialized | Specialized - Sensor TubeSensor |
| Russian movable-anode mechanotron for precision linear displacement and force measurement. Mechanical motion directly modulates electrode current, providing sensitive electrical readout. | ||||||||||
6MX1SSpecialized | Specialized - Sensor TubeSensor |
| IO - International Octal Russian dual movable-anode mechanotron for precision displacement and force measurement. Its differential mechanical-to-electrical conversion provides high sensitivity and long service life. | ||||||||||
6MX2BSpecialized | Specialized - Sensor TubeSensor |
| IO - International Octal Russian single movable-anode mechanotron for precision linear displacement and force measurement. Mechanical motion produces a sensitive proportional change in electrode current. | ||||||||||
6MX3SSpecialized | Specialized - Sensor TubeSensor |
| IO - International Octal Russian dual movable-anode mechanotron for precision displacement and force measurement. Its differential electrode system provides high mechanical-to-electrical sensitivity. | ||||||||||
6MX4SSpecialized | Specialized - Sensor TubeSensor |
| IO - International Octal Russian dual movable-anode mechanotron for precision linear displacement and force measurement. It provides especially high current sensitivity to very small mechanical movement. | ||||||||||
6MX5SSpecialized | Specialized - Sensor TubeSensor |
| IO - International Octal Russian dual movable-anode mechanotron for precision displacement and force measurement. Its differential construction converts small mechanical movement into a sensitive electrical-current change. | ||||||||||
6MX7SSpecialized | Specialized - Sensor TubeSensor |
| Russian precision mechanotron displacement and force transducer with high sensitivity, low drift, and long rated service life. Mechanical movement directly modulates electrode current. | ||||||||||
F9066Specialized | Specialized - Sensor TubeSensor | - | Electrochemical mercury coulometer for measuring electric charge or elapsed operating time. Electrochemical transfer of mercury displaces a visible electrolyte index proportional to accumulated charge. | ||||||||||
SY1301Specialized | Specialized - Sensor TubeSensorDirectly heated |
| 8 pins Omegatron mass-spectrometer sensing tube for residual-gas analysis. Crossed electric and magnetic fields separate ions by mass-to-charge ratio for vacuum-system composition measurement. | ||||||||||
SY1301ASpecialized | Specialized - Sensor TubeSensorDirectly heated | - | 8 pins Calibrated SY1301 Omegatron mass-spectrometer tube for quantitative residual-gas analysis. A tungsten emitter and crossed electric and magnetic fields permit measurement of individual gas partial pressures. | ||||||||||
T2H60JASpecialized | Specialized - Sensor TubeSensor | - | Disc-seal UHF thermocouple for monitoring RF power in resonators, waveguides, and coaxial lines from approximately 300 MHz to 6 GHz. | ||||||||||
T2H60JBSpecialized | Specialized - Sensor TubeSensor | - | Disc-seal UHF thermocouple for monitoring microwave power in resonators, waveguides, and coaxial transmission lines from roughly 300 MHz to 6 GHz. | ||||||||||
TH1Specialized | Specialized - Sensor TubeSensor | - | Subminiature vacuum thermocouple current sensor for low-current instrumentation. Electrical current heats an internal element and produces a small thermoelectric voltage proportional to current. | ||||||||||
TH3Specialized | Specialized - Sensor TubeSensor | - | Subminiature vacuum thermocouple current sensor for moderate low-current measurement. Heater current produces a small thermoelectric voltage proportional to electrical input. | ||||||||||
TH4Specialized | Specialized - Sensor TubeSensor | - | Vacuum thermocouple current-measuring device for moderate currents. Electrical heating generates a small thermoelectric voltage used for current indication and instrumentation. | ||||||||||
TH5Specialized | Specialized - Sensor TubeSensor | - | Subminiature vacuum thermocouple current sensor for currents up to several hundred milliamperes. Heater current produces a proportional millivolt-level thermoelectric output. | ||||||||||
TH71Specialized | Specialized - Sensor TubeSensor | - | Indirectly heated subminiature vacuum thermocouple for low-current electrical measurement. Thermal coupling converts heater current into a small thermoelectric instrumentation signal. | ||||||||||
TH73Specialized | Specialized - Sensor TubeSensor | - | Indirectly heated subminiature vacuum thermocouple for moderate low-current measurement. Heater current is converted into a small thermoelectric output voltage. | ||||||||||
TH75Specialized | Specialized - Sensor TubeSensor | - | Indirectly heated subminiature vacuum thermocouple for currents up to several hundred milliamperes. Thermal conversion provides a millivolt-level measurement signal. | ||||||||||
TH91Specialized | Specialized - Sensor TubeSensor | - | Indirectly heated subminiature vacuum thermocouple for very low-current measurement. It converts electrical heating into a small thermoelectric voltage for precision instrumentation. | ||||||||||
TH93Specialized | Specialized - Sensor TubeSensor | - | Indirectly heated subminiature vacuum thermocouple for moderate low-current measurement. Heater current produces a small thermoelectric voltage suitable for instrumentation. | ||||||||||
TH95Specialized | Specialized - Sensor TubeSensor | - | Indirectly heated subminiature vacuum thermocouple for currents up to several hundred milliamperes. It produces a small thermoelectric output proportional to electrical heating. | ||||||||||
TT26Specialized | Specialized - Sensor TubeSensor | - | Argon-filled Bendix Y-type DC Convectron vertical-reference sensor. Gas convection around heated elements produces an electrical indication of inclination for precision attitude measurement. | ||||||||||
TT27Specialized | Specialized - Sensor TubeSensor | - | Bendix DC Convectron vertical-reference sensor using gas convection around a heated filament to provide an electrical indication of tilt. The approximately 400 °C filament establishes the thermal convection pattern whose displacement with inclination produces the sensing signal. |