Data set 01
1957 Philips Receiving and Amplifying Tubes
Published operating points and test conditions from this source.
Sensor
Other
Maximum heater current
350 mA
Characteristics
Heater current for 12 mV output
200 mA
Specialized - Sensor Tube ·Sensor
Subminiature vacuum thermocouple current sensor for currents up to several hundred milliamperes. Heater current produces a proportional millivolt-level thermoelectric output.
Thermocouple current-measuring device with maximum heater current of 350 mA.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
No fixed ratings are recorded for this section.
Thermocouple measuring element; current ranges retained as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Maximum heater current
350 mA
Heater current for 12 mV output
200 mA
Data set 02
Published operating points and test conditions from this source.
Heater current range
0-300 mA
Approximate square-law proportional range
0-100 mA
Heater current at 12 mV output
200 mA
Heater resistance
1.2 ohm
Thermocouple resistance
3.5 ohm
Response time
10 sec
Maximum heater current for 1 minute
350 mA
Maximum heater-to-thermocouple voltage
100 V