Skip to main content

Specialized tube type

Specialized - Sensor Tube vacuum tubes

Specialized - Sensor Tube records in Tube Tinker cover 30 tube designations, including 34 preserved original datasheets. Compare bases, sockets, heater requirements, construction, exact variations, and directional replacement options.

Search this type in the catalog →
Tube records
30
Original datasheets
34
Variation families
0
Tubes with alternatives
0

About Specialized - Sensor Tube tubes

If the tube is described as a sensor tube then apply this type.

Electrical range

Nominal heater voltage
1.15–6.3 V
Nominal heater current
0.127–0.41 A

Common specialized - sensor tube characteristics

These are the most frequently recorded attributes among tubes in this category.

Bases

  • SUBMINIATURE9
  • B9G1

Sockets

  • IO5

Constructions

  • Sensor30

Specialized - Sensor Tube tube list

Page 1 of 1

Open advanced catalog filters →
  • 4001

    Sensor

    Contact-type vacuum thermocouple with heater wire joined directly to the thermojunction. It converts electrical current into a small thermoelectric voltage for precision current measurement.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 56006

    Sensor

    Omegatron mass-spectrometer sensing tube with platinum electrodes and tungsten cathode. It analyzes residual gases by separating ions according to mass-to-charge ratio and measuring partial pressures.

    Base
    B9G
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 6361

    Sensor

    Convectron vertical-reference sensor using heated filaments and gas convection to detect tilt electronically. Two units can form an orthogonal bridge system for precision inclination measurement.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 6MDX1B

    Sensor

    Russian mechanotron transducer using a movable electrode to measure excess pressure electrically. Mechanical pressure displacement changes electrode current for precision instrumentation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 6MDX3B

    Sensor

    Russian mechanotron pressure transducer for precision excess-pressure measurement. Mechanical movement of an internal electrode produces a corresponding electrical-current change.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 6MUX6P

    Sensor

    Russian mechanotron transducer for measuring angular displacement in a vertical plane. Internal mechanical movement produces an electrical output proportional to angle.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 6MX1B

    Sensor

    Russian movable-anode mechanotron for precision linear displacement and force measurement. Mechanical motion directly modulates electrode current, providing sensitive electrical readout.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 6MX1S

    Sensor

    Russian dual movable-anode mechanotron for precision displacement and force measurement. Its differential mechanical-to-electrical conversion provides high sensitivity and long service life.

    Base
    Not recorded
    Socket
    IO
    Heater
    6.3 V
    Sections
    1
  • 6MX2B

    Sensor

    Russian single movable-anode mechanotron for precision linear displacement and force measurement. Mechanical motion produces a sensitive proportional change in electrode current.

    Base
    Not recorded
    Socket
    IO
    Heater
    6.3 V
    Sections
    1
  • 6MX3S

    Sensor

    Russian dual movable-anode mechanotron for precision displacement and force measurement. Its differential electrode system provides high mechanical-to-electrical sensitivity.

    Base
    Not recorded
    Socket
    IO
    Heater
    6.3 V
    Sections
    1
  • 6MX4S

    Sensor

    Russian dual movable-anode mechanotron for precision linear displacement and force measurement. It provides especially high current sensitivity to very small mechanical movement.

    Base
    Not recorded
    Socket
    IO
    Heater
    6.3 V
    Sections
    1
  • 6MX5S

    Sensor

    Russian dual movable-anode mechanotron for precision displacement and force measurement. Its differential construction converts small mechanical movement into a sensitive electrical-current change.

    Base
    Not recorded
    Socket
    IO
    Heater
    6.3 V
    Sections
    1
  • 6MX7S

    Sensor

    Russian precision mechanotron displacement and force transducer with high sensitivity, low drift, and long rated service life. Mechanical movement directly modulates electrode current.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • F9066

    Sensor

    Electrochemical mercury coulometer for measuring electric charge or elapsed operating time. Electrochemical transfer of mercury displaces a visible electrolyte index proportional to accumulated charge.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • SY1301

    Sensor

    Omegatron mass-spectrometer sensing tube for residual-gas analysis. Crossed electric and magnetic fields separate ions by mass-to-charge ratio for vacuum-system composition measurement.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    1.15 V
    Sections
    1
  • SY1301A

    Sensor

    Calibrated SY1301 Omegatron mass-spectrometer tube for quantitative residual-gas analysis. A tungsten emitter and crossed electric and magnetic fields permit measurement of individual gas partial pressures.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • T2H60JA

    Sensor

    Disc-seal UHF thermocouple for monitoring RF power in resonators, waveguides, and coaxial lines from approximately 300 MHz to 6 GHz.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • T2H60JB

    Sensor

    Disc-seal UHF thermocouple for monitoring microwave power in resonators, waveguides, and coaxial transmission lines from roughly 300 MHz to 6 GHz.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH1

    Sensor

    Subminiature vacuum thermocouple current sensor for low-current instrumentation. Electrical current heats an internal element and produces a small thermoelectric voltage proportional to current.

    Base
    SUBMINIATURE
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH3

    Sensor

    Subminiature vacuum thermocouple current sensor for moderate low-current measurement. Heater current produces a small thermoelectric voltage proportional to electrical input.

    Base
    SUBMINIATURE
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH4

    Sensor

    Vacuum thermocouple current-measuring device for moderate currents. Electrical heating generates a small thermoelectric voltage used for current indication and instrumentation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH5

    Sensor

    Subminiature vacuum thermocouple current sensor for currents up to several hundred milliamperes. Heater current produces a proportional millivolt-level thermoelectric output.

    Base
    SUBMINIATURE
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH71

    Sensor

    Indirectly heated subminiature vacuum thermocouple for low-current electrical measurement. Thermal coupling converts heater current into a small thermoelectric instrumentation signal.

    Base
    SUBMINIATURE
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH73

    Sensor

    Indirectly heated subminiature vacuum thermocouple for moderate low-current measurement. Heater current is converted into a small thermoelectric output voltage.

    Base
    SUBMINIATURE
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH75

    Sensor

    Indirectly heated subminiature vacuum thermocouple for currents up to several hundred milliamperes. Thermal conversion provides a millivolt-level measurement signal.

    Base
    SUBMINIATURE
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH91

    Sensor

    Indirectly heated subminiature vacuum thermocouple for very low-current measurement. It converts electrical heating into a small thermoelectric voltage for precision instrumentation.

    Base
    SUBMINIATURE
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH93

    Sensor

    Indirectly heated subminiature vacuum thermocouple for moderate low-current measurement. Heater current produces a small thermoelectric voltage suitable for instrumentation.

    Base
    SUBMINIATURE
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH95

    Sensor

    Indirectly heated subminiature vacuum thermocouple for currents up to several hundred milliamperes. It produces a small thermoelectric output proportional to electrical heating.

    Base
    SUBMINIATURE
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TT26

    Sensor

    Argon-filled Bendix Y-type DC Convectron vertical-reference sensor. Gas convection around heated elements produces an electrical indication of inclination for precision attitude measurement.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TT27

    Sensor

    Bendix DC Convectron vertical-reference sensor using gas convection around a heated filament to provide an electrical indication of tilt. The approximately 400 °C filament establishes the thermal convection pattern whose displacement with inclination produces the sensing signal.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1