Skip to main content

Electronic tube type

Power - Triode (over 1000V 100W) vacuum tubes

Power - Triode (over 1000V 100W) records in Tube Tinker cover 912 tube designations, including 2,241 preserved original datasheets. Compare bases, sockets, heater requirements, construction, exact variations, and directional replacement options.

Search this type in the catalog →
Tube records
912
Original datasheets
2,241
Variation families
16
Tubes with alternatives
7

About Power - Triode (over 1000V 100W) tubes

Tubes of this type must have a power triode section which takes priority. The max plate watt rating must be over 100 watts and max plate volts over 1000 volts. Qualification also says that this tube did NOT qualify as "HorizontalSweep" or "VerticalSweep"

Electrical range

Nominal heater voltage
3.2–76 V
Nominal heater current
0.24–1,900 A

Common power - triode (over 1000v 100w) characteristics

These are the most frequently recorded attributes among tubes in this category.

Bases

  • E11-816

Sockets

  • UX411
  • JUMBO4B7
  • B4B6
  • E116
  • MEDIUM4BAYONET6
  • GIANT55
  • J45
  • SPECIAL45

Constructions

  • Triode912

Power - Triode (over 1000V 100W) tube list

Page 2 of 19

Open advanced catalog filters →
  • 3C-150A

    Triode

    Standard Valves 3C/150-A directly heated thoriated-tungsten RF power triode for broadcast transmitters and modulators, rated 2500 V anode, 150 W dissipation and 10 V 3.4 A filament.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    10 V
    Sections
    1
  • 3C270A

    Triode

    Industrial power triode intended for substantial radio-frequency power service. Manufacturer documentation places it in transmitting-class operation, with ratings and operating data centered on high-power RF amplification.

    Base
    Not recorded
    Socket
    GIANT4BAYONET
    Heater
    14 V
    Sections
    1
  • 3C27B

    Triode

    Microwave coaxial triode for pulsed oscillator service to approximately 1150 MHz.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3C350E

    Triode

    Heavy-filament directly heated RF transmitting triode for substantial radio-frequency power service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    10 V
    Sections
    1
  • 3C36

    Triode

    UHF power triode designed for resonant-cavity operation in high-frequency transmitting equipment.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3C37

    Triode

    Microwave coaxial triode for pulsed oscillator service to approximately 1150 MHz.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3C800E

    Triode

    Heavy-filament directly heated triode for high-power transmitting and RF service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CI50A

    Triode

    RF transmitting triode with thoriated-tungsten filament for high-frequency power amplification.

    Base
    Not recorded
    Socket
    LARGE4BAYONET
    Heater
    10 V
    Sections
    1
  • 3CPX100A5

    Triode

    Planar triode for high-frequency electronic service. Available source material confirms planar construction without establishing a narrower application confidently.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6 V
    Sections
    1
  • 3CPX800A7

    Triode

    High-mu power triode for substantial RF amplification and transmitting service.

    Base
    E11-81
    Socket
    E11
    Heater
    13.5 V
    Sections
    1
  • 3CV1500A7

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    5 V
    Sections
    1
  • 3CV30000A3

    Triode

    Very-high-power directly heated triode for industrial and transmitting RF service, using an exceptionally heavy filament.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CV30000H3

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CW10000H3

    Triode

    Water-cooled ceramic-metal medium-mu power triode for industrial radio-frequency heating service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW20000A1

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW20000A3

    Triode

    Water-cooled ceramic-metal medium-mu power triode for industrial RF, grounded-grid, and linear-amplifier service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW20000A7

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW20000H3

    Triode

    Water-cooled ceramic-metal medium-mu power triode for industrial radio-frequency heating service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW20000H7

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW25000A3

    Triode

    Water-cooled ceramic-metal power triode designed primarily for industrial radio-frequency heating, with a 25-kilowatt anode-dissipation class.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CW30000H3

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CW30000H7

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CW40000H3

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    10 V
    Sections
    1
  • 3CW5000A1

    Triode

    Low-mu water-cooled power triode for high-power audio amplifier or modulator service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW5000A3

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW5000F1

    Triode

    Low-mu water-cooled power triode with flexible leads for high-power audio amplifier or modulator service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW5000F3

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CW5000H3

    Triode

    Water-cooled ceramic-metal industrial power triode for high-power RF generation, amplification, or modulation. Its manufacturer ratings emphasize continuous transmitting duty with high plate dissipation and substantial power handling.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX10000A1

    Triode

    Ceramic-metal industrial power triode designed for high-power RF amplifier, oscillator, or modulator service. Manufacturer data emphasize transmitting duty, substantial plate dissipation, and the cooling provisions required for continuous professional operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX10000A3

    Triode

    Ceramic-metal industrial power triode designed for high-power RF amplifier, oscillator, or modulator service. Manufacturer data emphasize transmitting duty, substantial plate dissipation, and the cooling provisions required for continuous professional operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX10000A7

    Triode

    Ceramic-metal industrial power triode designed for high-power RF amplifier, oscillator, or modulator service. Manufacturer data emphasize transmitting duty, substantial plate dissipation, and the cooling provisions required for continuous professional operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX10000H3

    Triode

    Ceramic-metal industrial power triode designed for high-power RF amplifier, oscillator, or modulator service. Manufacturer data emphasize transmitting duty, substantial plate dissipation, and the cooling provisions required for continuous professional operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX10000U7

    Triode

    Ceramic-metal industrial power triode designed for high-power RF amplifier, oscillator, or modulator service. Manufacturer data emphasize transmitting duty, substantial plate dissipation, and the cooling provisions required for continuous professional operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    15 V
    Sections
    1
  • 3CX1000A7

    Triode

    Ceramic-metal industrial power triode designed for high-power RF amplifier, oscillator, or modulator service. Manufacturer data emphasize transmitting duty, substantial plate dissipation, and the cooling provisions required for continuous professional operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    5 V
    Sections
    1
  • 3CX15000A3

    Triode

    Ceramic-metal industrial power triode designed for high-power RF amplifier, oscillator, or modulator service. Manufacturer data emphasize transmitting duty, substantial plate dissipation, and the cooling provisions required for continuous professional operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CX15000A7

    Triode

    High-mu ceramic-metal power triode for grounded-grid RF amplification and oscillator service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CX15000H3

    Triode

    Air-cooled ceramic-metal industrial power triode intended for RF heating and other high-power RF amplifier or modulator service. It provides 15 kW plate dissipation and high-voltage operation for demanding continuous-duty installations.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CX1500A7

    Triode

    Rugged high-mu ceramic-metal transmitting triode for cathode-driven Class-AB2 or Class-B audio and RF amplification, including VHF and plate-modulated Class-C service. Published VHF operation reaches the FM broadcast band.

    Base
    Not recorded
    Socket
    SK2200
    Heater
    5 V
    Sections
    1
  • 3CX20000A3

    Triode

    Forced-air-cooled ceramic power triode for industrial oscillators and communications amplifiers. Its 20 kW plate-dissipation class and high-current capability suit large RF generators, transmitters, and modulator systems.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CX20000A7

    Triode

    High-mu ceramic-metal power triode designed for grounded-grid RF amplification. With 20 kW plate dissipation and multi-ampere plate-current capability, it serves very-high-power professional transmitting systems.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CX20000H3

    Triode

    Medium-mu ceramic industrial power triode for RF heating, AM broadcast, and modulation. Its 20 kW plate dissipation and high-voltage capability suit large continuous-duty industrial and transmitting installations.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • 3CX2500A3

    Triode

    All-ceramic-and-metal medium-mu transmitting triode for RF amplification, oscillation, and modulation. It offers about 2.5 kW plate dissipation and carries full ratings into the VHF region for professional transmitter service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX2500F3

    Triode

    Forced-air-cooled medium-mu power triode for RF and audio-frequency amplifier or modulator service. Its 2.5 kW plate-dissipation rating and several-kilovolt operation suit substantial transmitting and industrial power stages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX2500H3

    Triode

    Forced-air-cooled ceramic/metal power triode for industrial RF heating, RF amplification, and modulator service. Rated for 2.5 kW plate dissipation and about 10 kW typical industrial-RF output at 6 kV.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX3000A1

    Triode

    Rugged low-mu ceramic power triode intended primarily for high-power audio-amplifier and modulator service. Forced-air cooling permits 3 kW plate dissipation, with high-current operation suited to large professional power stages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX3000A7

    Triode

    Very high-mu ceramic power triode designed for grounded-grid RF amplification and also usable in high-power audio service. Forced-air cooled, with multi-kilowatt dissipation and published operation extending into VHF.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX3000F1

    Triode

    Low-mu forced-air-cooled power triode intended for high-power audio-amplifier and modulator service. Its 3 kW plate-dissipation capability and high-current operation suit large broadcast and professional power stages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1
  • 3CX3000F7

    Triode

    High-mu forced-air-cooled power triode with flexible grid and filament leads, intended principally for grounded-grid RF amplification. It combines multi-kilowatt dissipation with high power gain and substantial RF output.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    7.5 V
    Sections
    1