Skip to main content

Power - Triode (over 1000V 100W) ·Triode

3C-150A

Standard Valves 3C/150-A directly heated thoriated-tungsten RF power triode for broadcast transmitters and modulators, rated 2500 V anode, 150 W dissipation and 10 V 3.4 A filament.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
4
Nominal heater
10 V / 3.4 A

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
4
Nominal heater voltage
10 V
Nominal heater current
3.4 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
3800 Ω
Transconductance
0.00475 S
Amplification factor
18
Max plate voltage
2500 V
Max plate dissipation
150 W

Standard Valves 3C/150-A directly heated thoriated-tungsten RF triode. At Va 1000 V and Ia 150 mA: mu 18, rp 3800 Ω, gm 0.00475 A/V. Maximum DC anode voltage 2500 V, anode current 200 mA, anode dissipation 150 W, valid through 20 MHz; at 60 MHz anode voltage limit 2000 V. Grid-anode capacitance 7.3 pF, grid-filament 8.6 pF, anode-filament 1.1 pF. Class B balanced AF pair 500–600 W, Class B RF telephony ~80 W per tube, Class C modulated RF 250–270 W, Class C unmodulated RF 300–380 W. Printed maximum RF grid current '10 A' requires separate confirmation due to possible source ambiguity.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

No source-specific operating conditions are recorded.