Skip to main content

Power - Triode (over 1000V 100W) ·Triode

3CX2500H3

Forced-air-cooled ceramic/metal power triode for industrial RF heating, RF amplification, and modulator service. Rated for 2.5 kW plate dissipation and about 10 kW typical industrial-RF output at 6 kV.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
7.5 V / 52 A

Description

Forced-air-cooled ceramic/metal industrial RF-heating power triode.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
7.5 V
Nominal heater current
52 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.02 S
Amplification factor
20
Max plate voltage
6000 V
Max plate dissipation
2500 W
Max grid dissipation
400 W
Max cathode current
2.5 A

Maximum ratings promoted from the printed service-rating tables; typical operating values are preserved as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Maximum plate voltage

    6000 V

  • Maximum plate/cathode current

    2.5 A

  • Maximum plate dissipation

    2500 W

  • Maximum grid dissipation

    400 W

Data set 02

1965 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater/filament voltage

    7.5 V

  • Heater/filament current

    50 A

  • Amplification factor

    20

  • Transconductance

    20000 uS

Capacitance

  • Input/grid-cathode capacitance

    35 pF

  • Output/plate-cathode capacitance

    0.9 pF

  • Feedback/grid-plate capacitance

    20 pF

Other

  • Maximum plate voltage

    6000 V

  • Maximum plate dissipation

    2500 W

  • Maximum grid dissipation

    150 W

  • Maximum plate/cathode current

    2.5 A

  • Frequency for maximum ratings

    75 MHz

  • Industrial RF plate input maximum

    12500 W

    IndustrialRF

  • Typical industrial RF plate voltage

    6000 V

    IndustrialRF

  • Typical industrial RF plate output

    10000 W

    IndustrialRF

Data set 03

199X Svetlana

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Current @

    7.5 V

    or modulator service. The ceramic is glazed to

  • Input

    36 pF

    or modulator service. The ceramic is glazed to

  • Output

    0.9 pF

    or modulator service. The ceramic is glazed to

  • Feedback

    20 pF

    or modulator service. The ceramic is glazed to

  • Maximum frequency for full ratings (CW)

    75 MHz

    or modulator service. The ceramic is glazed to

Other

  • DC plate voltage

    6000 V

    Maximum Ratings

  • DC plate current

    2.5 A

    Maximum Ratings

  • Plate dissipation

    4000 W

    Maximum Ratings

  • Grid dissipation

    150 W

    Maximum Ratings

  • DC grid voltage

    -1000 V

    Maximum Ratings

  • DC grid current

    400 mA

    Maximum Ratings

  • (Frequencies to

    30 MHz

    Typical Operation

  • DC plate voltage 4000 5000

    6000 V

    Typical Operation

  • DC plate current 2.5 2.5

    2.08 A

    Typical Operation

  • DC grid voltage* -300 -450

    -500 V

    Typical Operation

  • DC grid current* 245 265

    180 mA

    Typical Operation

  • Peak RF grid voltage* 580 750

    765 V

    Typical Operation

  • Driving Power* 142 197

    136 W

    Typical Operation

  • Grid dissipation* 68 78

    46 W

    Typical Operation

  • Plate input power 10,000 12,500

    12500 W

    Typical Operation

  • Plate dissipation 2500 2500

    2500 W

    Typical Operation

  • Plate output power 7500 10,000

    10000 W

    Typical Operation

  • DC plate voltage

    5500 V

    Maximum Ratings

  • DC plate current

    2 A

    Maximum Ratings

  • Plate dissipation

    2670 W

    Maximum Ratings

  • Grid dissipation

    150 W

    Maximum Ratings

  • DC grid voltage

    -1000 V

    Maximum Ratings

  • (Frequencies to

    110 MHz

    Typical Operation

  • DC plate voltage 4000 4500

    5000 V

    Typical Operation

  • DC plate current 1.67 1.47

    1.25 A

    Typical Operation

  • DC grid voltage -450 -500

    -550 V

    Typical Operation

  • DC grid current* 180 140

    150 mA

    Typical Operation

  • Peak RF grid voltage* 685 715

    760 V

    Typical Operation

  • Driving power 125 100

    115 W

    Typical Operation

  • Grid dissipation* 43 30

    32 W

    Typical Operation

  • DC plate input power 6670 6615

    6250 W

    Typical Operation

  • Plate dissipation 1670 1315

    950 W

    Typical Operation

  • Plate output power 5000 5300

    5300 W

    Typical Operation

  • DC plate voltage

    6000 V

    Maximum Ratings (per tube)

  • DC plate current

    2.5 A

    Maximum Ratings (per tube)

  • Plate dissipation

    4000 W

    Maximum Ratings (per tube)

  • Grid dissipation

    150 W

    Maximum Ratings (per tube)

  • DC grid voltage

    -1000 V

    Maximum Ratings (per tube)

  • DC plate voltage 4000 5000

    6000 V

    Typical Operation (two tubes sinusoidal waveform)

  • Zero-signal DC plate current* 0.6 0.5

    400 mA

    Typical Operation (two tubes sinusoidal waveform)

  • Maximum-signal DC plate current 4.0 3.2

    3 A

    Typical Operation (two tubes sinusoidal waveform)

  • DC grid voltage ** -150 -190

    -240 V

    Typical Operation (two tubes sinusoidal waveform)

  • Peak AF grid voltage (per tube)* 340 360

    390 V

    Typical Operation (two tubes sinusoidal waveform)

  • Maximum-signal peak driving power* 340 230

    225 W

    Typical Operation (two tubes sinusoidal waveform)

  • Maximum-signal nominal driving power* 170 115

    113 W

    Typical Operation (two tubes sinusoidal waveform)

  • Load resistance, plate-to-plate 2200 3600

    4650 Ohms

    Typical Operation (two tubes sinusoidal waveform)

  • Maximum-signal plate output power 11,000 11,000

    13000 W

    Typical Operation (two tubes sinusoidal waveform)

  • Filament current at

    7.5 V

    Typical Operation (two tubes sinusoidal waveform)

  • Input 29.2

    40.2 pF

    Typical Operation (two tubes sinusoidal waveform)

  • Output 0.6

    1.2 pF

    Typical Operation (two tubes sinusoidal waveform)

  • Feedback 16.8

    23.2 pF

    Typical Operation (two tubes sinusoidal waveform)

  • DC grid bias for Eb =3000, Ib =0.83A -67

    -100 V

    Typical Operation (two tubes sinusoidal waveform)

  • the ceramic/metal seals below

    250 ˚C

    Typical Operation (two tubes sinusoidal waveform)

  • temperatures below

    225 ˚C

    Typical Operation (two tubes sinusoidal waveform)

  • temperature of

    40 ˚C

    Typical Operation (two tubes sinusoidal waveform)