Skip to main content

Power - Triode (over 1000V 100W) ·Triode

3CX15000A3

Ceramic-metal industrial power triode designed for high-power RF amplifier, oscillator, or modulator service. Manufacturer data emphasize transmitting duty, substantial plate dissipation, and the cooling provisions required for continuous professional operation.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 160 A

Description

The EIMAC 3CX15000A3 is a air-cooled medium-mu ceramic/metal power triode for industrial rf heating, fm, and linear-amplifier service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
160 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
20
Max plate voltage
8000 V
Max plate dissipation
15000 W
Max grid dissipation
500 W
Max cathode current
6 A

Maximum ratings promoted from the printed service-rating tables; typical operating values are preserved as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Triode

Capacitance

  • Grid-Filament — — — — — — — —« — - _— 55 pF

    55 pF

  • Plate-Filament, max, — — — — — — — — — 1.4 pF

    1.4 pF

  • Grid-Plate - — = — = — = = = — — — 34 pF

    34 pF

  • Grid-Filament — — = = — - — — 60 pF

    60 pF

  • Grid-Plate - — — — = — — — — 38 pF

    38 pF

Other

  • Maximum plate voltage

    8000 V

  • Maximum plate/cathode current

    6 A

  • Maximum plate dissipation

    15000 W

  • Maximum grid dissipation

    500 W

Data set 02

1975 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    20

  • Heater/filament voltage

    6.3 V

  • Heater/filament current

    160 A

Other

  • Maximum plate voltage

    8000 V

  • Maximum plate dissipation

    15000 W

  • Maximum grid dissipation

    500 W

  • Maximum cathode/plate current

    6 A

  • Frequency for maximum ratings

    100 MHz

  • Class-C maximum plate voltage

    8000 V

    ClassC

  • Plate-modulated maximum plate voltage

    6500 V

    PlateModulated

  • Recommended maximum grid current

    1 A

Capacitance

  • Input/grid-filament capacitance

    55 to 55 pF

  • Output/plate-filament capacitance

    1.4 to 1.4 pF

  • Feedback/grid-plate capacitance

    34 to 34 pF

Construction

  • Cooling

    Forced air

Data set 03

1976 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    20

  • Heater/filament voltage

    6.3 V

  • Heater/filament current

    160 A

Other

  • Maximum plate voltage

    8000 V

  • Maximum plate dissipation

    15000 W

  • Maximum grid dissipation

    500 W

  • Maximum cathode/plate current

    6 A

  • Frequency for maximum ratings

    100 MHz

  • Class-C maximum plate voltage

    8000 V

    ClassC

  • Plate-modulated maximum plate voltage

    6500 V

    PlateModulated

  • Recommended maximum grid current

    1 A

Capacitance

  • Input/grid-filament capacitance

    55 to 55 pF

  • Output/plate-filament capacitance

    1.4 to 1.4 pF

  • Feedback/grid-plate capacitance

    34 to 34 pF

Construction

  • Cooling

    Forced air

Data set 04

199X Svetlana

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Current @

    7.5 V

    General

  • Input

    55 pF

    General

  • Output

    34 pF

    General

  • Feedback

    1.4 pF

    General

  • Input

    55 pF

    General

  • Output

    1.4 pF

    General

  • Feedback

    34 pF

    General

  • Maximum frequency for full ratings (CW)

    100 MHz

    General

Other

  • DC plate voltage

    8000 V

    Maximum Ratings

  • DC plate current

    6 A

    Maximum Ratings

  • Plate dissipation

    15000 W

    Maximum Ratings

  • Grid dissipation

    500 W

    Maximum Ratings

  • DC plate voltage

    7000 V

    Typical operation

  • Zero-signal DC plate current

    1.5 A

    Typical operation

  • Single-tone DC plate current

    4.8 A

    Typical operation

  • Zero-signal DC grid voltage

    -270 V

    Typical operation

  • Max DC grid current

    400 mA

    Typical operation

  • Peak RF grid voltage

    540 V

    Typical operation

  • Peak driving power

    215 W

    Typical operation

  • Single-tone plate output power

    23000 W

    Typical operation

  • Resonant load impedance

    730 ohms

    Typical operation

  • DC plate voltage

    8000 V

    Maximum ratings (per tube)

  • DC plate current

    6 A

    Maximum ratings (per tube)

  • Plate dissipation

    15000 W

    Maximum ratings (per tube)

  • Grid dissipation

    500 W

    Maximum ratings (per tube)

  • DC plate voltage

    7000 V

    Typical operation

  • DC grid voltage

    -600 V

    Typical operation

  • Maximum-signal DC plate current

    6 A

    Typical operation

  • Maximum-signal DC grid current

    660 mA

    Typical operation

  • Peak AF grid voltage

    1040 V

    Typical operation

  • Driving power

    660 W

    Typical operation

  • Plate input power

    42000 W

    Typical operation

  • Plate output power

    30000 W

    Typical operation

  • Plate dissipation

    12000 W

    Typical operation

  • Resonant load impedance

    600 ohms

    Typical operation

  • may be exceeded. Plate overcurrent protec- below

    225 ˚C

    periods such as during tuning. Over-current Vdc Class A, B, or C service. The

  • tion should be provided to remove plate perature of

    40 ˚C

    periods such as during tuning. Over-current Vdc Class A, B, or C service. The