Skip to main content

Power - Triode (over 1000V 100W) ·Triode

3CX15000H3

Air-cooled ceramic-metal industrial power triode intended for RF heating and other high-power RF amplifier or modulator service. It provides 15 kW plate dissipation and high-voltage operation for demanding continuous-duty installations.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 162 A

Description

Air-cooled ceramic-metal industrial RF-heating power triode.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
162 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
20
Max plate voltage
12000 V
Max plate dissipation
15000 W
Max grid dissipation
500 W
Max cathode current
6 A

Maximum ratings promoted from the printed service-rating tables; typical operating values are preserved as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Triode

Capacitance

  • Plate-Filament - - - - 1.3 1.6 ppf

    1.6 pF

Other

  • Maximum plate voltage

    12000 V

  • Maximum plate/cathode current

    6 A

  • Maximum plate dissipation

    15000 W

  • Maximum grid dissipation

    500 W

Data set 02

199X Svetlana

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Current @

    7.5 V

    or modulator service. The ceramic is glazed to

  • Input

    55 pF

    or modulator service. The ceramic is glazed to

  • Output

    1.5 pF

    or modulator service. The ceramic is glazed to

  • Feedback

    34 pF

    or modulator service. The ceramic is glazed to

  • Maximum frequency for full ratings (CW)

    90 MHz

    or modulator service. The ceramic is glazed to

Other

  • DC plate voltage

    12000 V

    Maximum Ratings

  • DC plate current

    6 A

    Maximum Ratings

  • Plate dissipation

    15000 W

    Maximum Ratings

  • Grid dissipation

    500 W

    Maximum Ratings

  • DC grid voltage

    -1000 V

    Maximum Ratings

  • DC grid current

    -1 A

    Maximum Ratings

  • Plate input power

    60000 W

    Maximum Ratings

  • (Frequencies to

    30 MHz

    Typical Operation (under load)

  • DC plate voltage 7000

    10000 V

    Typical Operation (under load)

  • DC plate current 6.0

    5 A

    Typical Operation (under load)

  • DC grid voltage -600

    -800 V

    Typical Operation (under load)

  • DC grid current 660

    542 mA

    Typical Operation (under load)

  • Peak RF grid voltage 440

    400 V

    Typical Operation (under load)

  • Driving Power 660

    650 W

    Typical Operation (under load)

  • Grid dissipation 78

    46 W

    Typical Operation (under load)

  • Plate input power 42,000

    50000 W

    Typical Operation (under load)

  • Plate dissipation 12,000

    8800 W

    Typical Operation (under load)

  • Plate output power 30,000

    41200 W

    Typical Operation (under load)

  • Approximate load impedance 600

    1025 Ohms

    Typical Operation (under load)

  • exceed

    600 mA

    Typical Operation (under load)

  • the need for continuous grid current temperatures below

    225 ˚C

    Typical Operation (under load)

  • monitoring. air temperature of

    50 ˚C

    Typical Operation (under load)

  • simultaneously. Plate current overload

    30 MHz

    Typical Operation (under load)