- Base
- —
- Socket code
- —
- Sections
- 1
Cold-cathode trigger/pulse switching tube. Available source classification establishes pulse-trigger switching service without enough detail for a narrower operating description.
Cold-cathode trigger/pulse switching tube. Available source classification establishes pulse-trigger switching service without enough detail for a narrower operating description.
Cold-cathode trigger/pulse switching tube. Available source classification establishes pulse-trigger switching service without enough detail for a narrower operating description.
Cold-cathode gas-filled trigger tube for pulse and control circuits, explicitly co-designated with its corresponding Z-series type in Amperex documentation.
Cold-cathode gas-filled trigger tube for pulse and control circuits, explicitly co-designated with its corresponding Z-series type in Amperex documentation.
Cold-cathode gas-filled trigger tube for pulse and control circuits, explicitly co-designated with its corresponding Z-series type in Amperex documentation.
Nullode pulse-discharge switching tube with short blocking time for rapid trigger and pulse circuits.
Metallized nullode pulse-discharge switching tube related to LG71, intended for rapid trigger and pulse circuits.
Nullode pulse-discharge switching tube with approximately 1–2 microsecond blocking time for rapid pulse-control applications.
Cold-cathode trigger and pulse switching tube. Available source classification establishes gas-discharge trigger service without enough detail for a narrower operating description.
Cold-cathode trigger and pulse switching tube. Available source classification establishes gas-discharge trigger service without enough detail for a narrower operating description.
No source PDFs available.
B9A - Small-button Noval 9-contact
Cold-cathode trigger and pulse switching tube. Gas-discharge operation provides abrupt heaterless switching for pulse and control circuits.
Cold-cathode trigger tube for pulse and control circuits. Gas ionization provides abrupt heaterless switching in response to a trigger condition.
No source PDFs available.
| Expand sections | More | Electrical Summary | General Summary | ||
|---|---|---|---|---|---|
7709Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | Cold-cathode trigger/pulse switching tube. Available source classification establishes pulse-trigger switching service without enough detail for a narrower operating description. | ||
7710Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | Refer to variations | Cold-cathode trigger/pulse switching tube. Available source classification establishes pulse-trigger switching service without enough detail for a narrower operating description. | ||
7711Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | Cold-cathode gas-filled trigger tube for pulse and control circuits, explicitly co-designated with its corresponding Z-series type in Amperex documentation. | ||
7713Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | Cold-cathode gas-filled trigger tube for pulse and control circuits, explicitly co-designated with its corresponding Z-series type in Amperex documentation. | ||
7714Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | Refer to variations | Cold-cathode gas-filled trigger tube for pulse and control circuits, explicitly co-designated with its corresponding Z-series type in Amperex documentation. | ||
LG71Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | Nullode pulse-discharge switching tube with short blocking time for rapid trigger and pulse circuits. | ||
LG75Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | Metallized nullode pulse-discharge switching tube related to LG71, intended for rapid trigger and pulse circuits. | ||
LG76Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | Nullode pulse-discharge switching tube with approximately 1–2 microsecond blocking time for rapid pulse-control applications. | ||
Z71USpecialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | Cold-cathode trigger and pulse switching tube. Available source classification establishes gas-discharge trigger service without enough detail for a narrower operating description. | ||
Z71U0Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | Cold-cathode trigger and pulse switching tube. Available source classification establishes gas-discharge trigger service without enough detail for a narrower operating description. | ||
Z805USpecialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | Refer to variations | B9A - Small-button Noval 9-contact Cold-cathode trigger and pulse switching tube. Gas-discharge operation provides abrupt heaterless switching for pulse and control circuits. | ||
| Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | - | |||
Z9001Specialized | Specialized - Switching TubeTriggerPulseSwitchCold cathode | - | Cold-cathode trigger tube for pulse and control circuits. Gas ionization provides abrupt heaterless switching in response to a trigger condition. |