Skip to main content

Specialized - Switching Tube ·Thyratron

Z70U

Cold-cathode gas-discharge switching tube. Available source material confirms heaterless thyratron-type construction but does not establish a narrower application.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Z70U is a Other device in the supplied Amperex literature. Cold-cathode gas-filled trigger tube for pulse/control circuits; source explicitly co-designates the numeric and Z-series type.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max cathode current
3 mA

Subminiature cold-cathode trigger tube with positive starter and priming cathode for DC circuits.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1957 Philips Receiving and Amplifying Tubes

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • StarterIgnitionVoltageMinimum

    137 V

    AnodeVoltage=250V

  • StarterIgnitionVoltageMaximum

    153 V

    AnodeVoltage=250V

  • AnodeIgnitionVoltageMinimum

    325 V

  • MaintainingVoltageMinimum

    113 V

    AnodeCurrent=3mA

  • MaintainingVoltageMaximum

    121 V

    AnodeCurrent=3mA

  • CountingSpeedMinimum

    3 kHz

    DC counting

  • CountingSpeedMaximum

    5 kHz

    DC counting

Data set 02

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Anode voltage range

    200 to 310 V

    DC

  • Peak cathode current

    16 mA

  • Recommended priming resistor

    18 MOhm

  • Cathode current range

    2 to 4 mA

    DC

Characteristic

  • Starter-to-cathode breakdown voltage

    137 to 153 V

  • Anode-to-cathode sustaining voltage

    111 to 121 V

  • Anode-to-cathode breakdown voltage

    >325 V

Data set 03

1963 Philips Electron Tubes Handbook V2

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Starter breakdown voltage at 250 V supply

    137 to 153 V

  • Temperature coefficient of starter breakdown voltage

    -25 mV/degC

    Maximum

  • Anode maintaining voltage at 3 mA

    111 to 121 V

  • Anode-cathode breakdown voltage at starter 0 V

    340 to - V

    Minimum

  • Anode-to-primer breakdown voltage

    - to 200 V

    Maximum

  • Starter maintaining voltage

    105 to 125 V

    Ist=30uA; Ia=0

  • Anode breakdown delay time

    - to 5 us

    Maximum

Other

  • Minimum anode supply voltage for DC ignition

    200 to - V

  • Maximum anode supply voltage for pulsed ignition

    - to 310 V

  • Peak cathode current

    - to 200 mA

  • Average cathode current

    - to 5 mA

  • Primer current

    - to 12 uA

Data set 04

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Starter ignition voltage minimum

    137 V

  • Starter ignition voltage maximum

    153 V

  • Anode maintaining voltage

    117 V

    Ia=3mA

  • Anode ignition voltage

    325 V