Skip to main content

Specialized - Switching Tube ·TriggerPulseSwitch

Z71U0

Cold-cathode trigger and pulse switching tube. Available source classification establishes gas-discharge trigger service without enough detail for a narrower operating description.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Z71U0 is a Other device in the supplied Amperex literature. Cold-cathode gas-filled trigger tube for pulse/control circuits; source explicitly co-designates the numeric and Z-series type.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

TriggerPulseSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Cold-cathode gas-filled trigger tube for pulse/control circuits; source explicitly co-designates the numeric and Z-series type.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

TriggerPulseSwitch

Other

  • Anode voltage range

    125 to 165 V

    DC

  • Peak cathode current

    12 mA

Characteristic

  • Starter-to-cathode breakdown voltage

    73 to 90 V

  • Anode-to-cathode sustaining voltage

    54 to 68 V

  • Anode-to-cathode breakdown voltage

    >175 V