Skip to main content

Specialized - Switching Tube ·TriggerPulseSwitch

Z805U

Cold-cathode trigger and pulse switching tube. Gas-discharge operation provides abrupt heaterless switching for pulse and control circuits.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
B9A
Base pins
-
Nominal heater
-

Description

Z805U is a Other device in the supplied Amperex literature. Cold-cathode gas-filled trigger tube for pulse/control circuits; source explicitly co-designates the numeric and Z-series type.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

TriggerPulseSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Gas-filled cold-cathode relay tube with positive starter voltage for AC or DC service.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

TriggerPulseSwitch

Other

  • Anode voltage range

    250 to 450 V

    DC

  • Peak cathode current

    150 mA

  • Cathode current range

    5 to 25 mA

    DC

  • Anode voltage range AC

    180 to 275 V

    AC

Characteristic

  • Starter-to-cathode breakdown voltage

    137 to 155 V

  • Anode-to-cathode sustaining voltage

    118 to 128 V

  • Anode-to-cathode breakdown voltage

    >500 V

  • Starter-to-cathode breakdown voltage AC

    98 to 110 V

    AC

Data set 02

1963 Philips Electron Tubes Handbook V2

Published operating points and test conditions from this source.

SECTION 1

TriggerPulseSwitch

Other

  • AC mains voltage range

    180 to 275 V RMS

    AC

  • AC frequency range

    10 to 100 Hz

    AC

  • Cathode current range AC

    5 to 25 mA

    AC

  • DC anode supply voltage range

    250 to 450 V

    DC

  • Cathode current range DC

    5 to 25 mA

    DC

  • Peak cathode current

    - to 150 mA

    AC one cycle

Characteristic

  • Starter breakdown voltage DC

    137 to 155 V

    Vba=250-450V

  • Starter breakdown voltage AC

    98 to 110 V RMS

    Vba=200-250V RMS

  • Maximum transfer current at 250 V

    - to 100 uA

  • Starter maintaining voltage at 100 uA

    110 V

  • Anode maintaining voltage at 20 mA

    118 to 128 V

  • Anode-cathode breakdown voltage

    475 to - V

  • Negative anode-cathode breakdown voltage

    475 to - V

    Minimum