Skip to main content

Specialized tube type

Specialized - Switching Tube vacuum tubes

Specialized - Switching Tube records in Tube Tinker cover 582 tube designations, including 1,033 preserved original datasheets. Compare bases, sockets, heater requirements, construction, exact variations, and directional replacement options.

Search this type in the catalog →
Tube records
582
Original datasheets
1,033
Variation families
18
Tubes with alternatives
23

About Specialized - Switching Tube tubes

If the tube is described as a switching tube, transmit/receive etc. then apply this type.

Electrical range

Nominal heater voltage
0–27 V
Nominal heater current
0–1,800 A

Common specialized - switching tube characteristics

These are the most frequently recorded attributes among tubes in this category.

Bases

  • B12E2
  • B7G2
  • Duodecal2
  • Special 13-pin2
  • 4CK1
  • 4V1
  • 6AR1
  • 9AD1

Sockets

  • B9A23
  • UX415
  • IO12
  • B7G11
  • B12A5
  • SK1005
  • B26A4
  • B13B2

Constructions

  • MicrowaveTRSwitch215
  • SparkGapPulseSwitch85
  • CounterSelectorSwitch37
  • Tetrode37
  • Thyratron37
  • RelayControlSwitch33
  • SurgeProtector33
  • BeamSwitchingCommutator19

Specialized - Switching Tube tube list

Page 11 of 13

Open advanced catalog filters →
  • RT53

    SparkGapPulseSwitch

    The Russian RT53 is a controlled ceramic spark-gap device intended for ignition of pulsed light sources. It switches stored electrical energy into short, high-current discharges. Its compact construction supports repetitive triggering in specialized flash, optical, and pulsed-power apparatus.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • RT57

    SparkGapPulseSwitch

    The RT57 is a Russian controlled spark-gap switch designed for emergency protection of high-power electrical equipment. Its metal-glass envelope accommodates large pulsed discharge currents. The device is intended to redirect or discharge stored electrical energy when a protection circuit triggers.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • RU62

    SparkGapPulseSwitch

    The Russian RU62 is a controlled metal-ceramic spark-gap device intended for pulse commutation in compact X-ray equipment. Its switching structure handles high instantaneous currents and stored electrical energy. It is designed for specialized pulsed-power circuits requiring controlled electrical discharge.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • RU65

    SparkGapPulseSwitch

    The RU65 is a Russian controlled spark-gap switch intended for equipment protection and high-energy circuit commutation. Its metal-ceramic construction accommodates substantial pulse currents and stored energy. The device provides triggered electrical discharge in specialized industrial and pulsed-power systems.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • RU66

    SparkGapPulseSwitch

    The Russian RU66 is a controlled spark-gap switching device intended for laser firing systems and other high-current pulsed-power circuits. Its metal-glass construction supports the rapid discharge of stored electrical energy. It is designed for repetitive high-current triggering under specified pulse conditions.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • RU67

    SparkGapPulseSwitch

    The Soviet RU67 is a controlled spark-gap switching tube designed for regulating flash duration in pulsed light sources. Its glass-enclosed discharge structure switches stored electrical energy rapidly without a heated cathode. Operation is limited by breakdown voltage, pulse repetition rate, and electrode life.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • RU68

    SparkGapPulseSwitch

    The Soviet RU68 is a high-energy controlled spark-gap switch intended for electrohydraulic equipment. Its metal-glass construction accommodates high-voltage breakdown and exceptionally large transient currents. The device commutates substantial stored electrical energy in short pulses without requiring filament heating.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • RU69

    SparkGapPulseSwitch

    The Soviet RU69 is a controlled spark-gap switch developed for pulsed high-power light sources. Its metal-glass discharge structure transfers stored electrical energy through brief high-current pulses. Breakdown voltage, repetition frequency, and permissible switching energy determine its operating limits and service life.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • RYG10

    CounterSelectorSwitch

    Ten-position trochotron counter using controlled electron-beam motion to advance through stable counting positions for digital and instrumentation systems.

    Base
    Not recorded
    Socket
    TROCHOTRON14
    Heater
    6.3 V
    Sections
    1
  • RYG10_ERICSSON

    BeamSwitchingCommutator

    The Ericsson RYG10 Trochotron is a high-vacuum electron-beam switching tube designed as a ten-position electronic ring counter. A magnetic field steers the electron beam among specially shaped electrodes called spades. The device performs sequential counting and commutation without conventional mechanical switching contacts.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • RYG10_KG

    BeamSwitchingCommutator

    The Ericsson RYG10 is a ten-position beam-switching Trochotron intended for pulse counting, frequency division, and computing equipment. Its magnetic-field-controlled electron beam selects successive spade electrodes, providing electrical count outputs and visual indication. The device supports electronic decade-counting applications.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • S1021G

    ThermalDelaySwitch

    Miniature thermal-delay switch. Heater warm-up actuates sealed contacts after a controlled time interval for sequencing and protection.

    Base
    Not recorded
    Socket
    B7G
    Heater
    6.3 V
    Sections
    1
  • S1021K

    ThermalDelaySwitch

    Thermal-delay switching device of the S1021 family. Available source material supports delayed switching service without enough detail for a narrower operating description.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    6.3 V
    Sections
    1
  • S1031K

    ThermalDelaySwitch

    Miniature thermal-delay switch. Thermal actuation changes the sealed contact state after a controlled delay for sequencing and protective circuits.

    Base
    Not recorded
    Socket
    B7G
    Heater
    Not recorded
    Sections
    1
  • S1041K

    ThermalDelaySwitch

    Miniature thermal-delay switch. Heater-driven thermal movement operates sealed contacts after a controlled interval for electronic sequencing and protection.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • S340

    Thyratron

    Inert-gas internally triggered cold-cathode trigger tube for heavy-duty electronic relay and switching service. Heaterless discharge provides abrupt high-current control.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • SN4

    Thyratron

    Cold-cathode inert-gas switching tube for condenser-discharge circuits, stroboscopic light pulses, relays, and controls. Heaterless gas discharge provides rapid switching.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TG14

    SurgeProtector

    Bendix cold-cathode sealed spark gap for high-voltage overvoltage protection. Gas breakdown diverts damaging transients away from protected equipment.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TG20

    SurgeProtector

    Bendix cold-cathode sealed spark gap for high-voltage overvoltage protection. Gas-discharge breakdown safely shunts damaging voltage surges.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH2602

    MicrowaveTRSwitch

    Specialized microwave TR-switching tube. Available source material establishes microwave switching service but does not identify a narrower operating band or application.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH2604

    MicrowaveTRSwitch

    Specialized microwave TR-switching tube. Available source material establishes microwave switching service but does not identify a narrower operating band or application.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH2605

    MicrowaveTRSwitch

    Specialized microwave TR-switching tube. Available source material establishes microwave switching service but does not identify a narrower operating band or application.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH2606

    MicrowaveTRSwitch

    Specialized microwave TR-switching tube. Available source material establishes microwave switching service but does not identify a narrower operating band or application.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH2608

    MicrowaveTRSwitch

    Specialized microwave TR-switching tube. Available source material establishes microwave switching service but does not identify a narrower operating band or application.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH2609

    MicrowaveTRSwitch

    Specialized microwave TR-switching tube. Available source material establishes microwave switching service but does not identify a narrower operating band or application.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TRP8

    MicrowaveTRSwitch

    Wideband S-band passive receiver-protection plug-in cell containing three primed gas-discharge protection tubes for radar crystal protection.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TV3301

    MicrowaveTRSwitch

    Specialized dual-section microwave TR-switching device. Available source material establishes microwave switching construction but does not support a more specific functional description.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    2
  • TV3303A

    MicrowaveTRSwitch

    Specialized microwave TR-switching device. Available source material establishes microwave switching construction but does not support a more specific functional description.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TV3304A

    MicrowaveTRSwitch

    Specialized microwave TR-switching device. Available source material establishes microwave switching construction but does not support a more specific functional description.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TV3308

    MicrowaveTRSwitch

    Specialized microwave TR-switching device. Available source material establishes microwave switching construction but does not support a more specific functional description.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TV3309

    MicrowaveTRSwitch

    Specialized dual-section microwave TR-switching device. Available source material establishes microwave switching construction but does not support a more specific functional description.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    2
  • TV3340

    MicrowaveTRSwitch

    Preset broadband X-band crystal-protector gas-discharge tube operating across approximately 8.5–9.6 GHz, designed to protect sensitive microwave receiver components from transmitter energy.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TV3340B

    MicrowaveTRSwitch

    Phase-controlled X-band crystal-protector gas-discharge tube rated for high incident peak power, protecting microwave receiver components while introducing low attenuation when non-ionized.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TV3362

    MicrowaveTRSwitch

    Ku-band crystal-protector gas-discharge tube operating around 16–17 GHz over a wide temperature range, designed to protect microwave receiver components from high incident energy.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TV5927

    MicrowaveTRSwitch

    Broadband non-tunable S-band gas-filled TR switch operating around 3.07–3.53 GHz, using ignitor-assisted discharge to protect the receiver during high-power transmitter pulses.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA1

    SurgeProtector

    Rare-gas-filled low-voltage surge arrester for protecting low-current installations and cables against lightning, atmospheric overvoltages, and accidental contact with power lines.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA12

    SurgeProtector

    Inert-gas surge arrester designed to protect aerial lines and cables against lightning and atmospheric overvoltages by conducting when transient voltage exceeds its protective threshold.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA12U

    SurgeProtector

    Inert-gas surge arrester designed to protect aerial lines and cables against lightning and atmospheric overvoltages by conducting when transient voltage exceeds its protective threshold.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA230

    SurgeProtector

    Inert-gas surge arrester for telecommunication and signalling equipment, designed to protect circuits from lightning, earth-return, and other transient overvoltages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA245A

    SurgeProtector

    Pre-ionized inert-gas surge arrester for telecommunication and signalling systems, designed to provide reliable protection against lightning and earth-return overvoltages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA245B

    SurgeProtector

    Pre-ionized inert-gas surge arrester for telecommunication and signalling systems, designed to provide reliable protection against lightning and earth-return overvoltages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA350

    SurgeProtector

    Inert-gas surge arrester family for protecting telecommunication and signalling systems against lightning, earth-return, and other transient overvoltages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA350B

    SurgeProtector

    Pre-ionized inert-gas surge arrester with approximately 350 V nominal striking voltage, designed for transient-overvoltage protection in telecommunication and signalling systems.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA350U

    SurgeProtector

    Inert-gas surge arrester family for protecting telecommunication and signalling systems against lightning, earth-return, and other transient overvoltages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA600

    SurgeProtector

    Inert-gas surge arrester designed specifically to protect coaxial-cable amplifiers from lightning, earth-return, and related transient overvoltages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UA600U

    SurgeProtector

    Inert-gas surge arrester designed specifically to protect coaxial-cable amplifiers from lightning, earth-return, and related transient overvoltages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UAM120

    SurgeProtector

    Subminiature flying-lead surge arrester for protecting telecommunication and signalling installations against momentary low-energy surge voltages.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • UAM470

    SurgeProtector

    Subminiature flying-lead surge arrester with approximately 470 V nominal breakdown voltage, designed for momentary low-energy transient protection.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1