Specialized - Switching Tube ·MicrowaveTRSwitch

TH2608

Specialized microwave TR-switching tube. Available source material establishes microwave switching service but does not identify a narrower operating band or application.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

The TH2608 is an X-band crystal protector operating from about 8980 to 9180 MHz, combining a passive TR section with a two-stage varactor limiter for protection of sensitive microwave receiver devices.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

MicrowaveTRSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Published electrical data audited and retained in parameter table.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1972 Thomson CSF

Published operating points and test conditions from this source.

SECTION 1

MicrowaveTRSwitch

Other

  • puissance créte de

    10 kW

    puissance créte de 10 kW, mais peut supporter pen-

  • des puissances incidentes de I’'ordre de

    150 kW

    des puissances incidentes de I’'ordre de 150 kW.

  • Bandedefréquence ............. ..., [1]

    8980 MHz

    Bandedefréquence ............. ..., 8980 - 9170 MHz

  • Bandedefréquence ............. ..., [2]

    9170 MHz

    Bandedefréquence ............. ..., 8980 - 9170 MHz

  • Puissance maximaled’amorgage [1]

    30 W

    Puissance maximaled’amorgage . ............... - 30 40 mwW

  • Puissance maximaled’amorgage [2]

    40 W

    Puissance maximaled’amorgage . ............... - 30 40 mwW

  • Puissance de fuite dans la pointe {valeur créte maximale) [1]

    5 W

    Puissance de fuite dans la pointe {valeur créte maximale) - 0,5 1 w

  • Puissance de fuite dans la pointe {valeur créte maximale) [2]

    1 W

    Puissance de fuite dans la pointe {valeur créte maximale) - 0,5 1 w

  • Puissance de fuite dans lepalier . ............... — [1]

    20 W

    Puissance de fuite dans lepalier . ............... — 20 30 mwW

  • Puissance de fuite dans lepalier . ............... — [2]

    30 W

    Puissance de fuite dans lepalier . ............... — 20 30 mwW

  • Puissancecréte a l'entrée . . .................. - —

    10 kW

    Puissancecréte a l'entrée . . .................. - — 10 kW

  • Puissance créte accidentelle [1]

    3 kW

    Puissance créte accidentelle 3 I'entrée {pendant 5 mn max.) - - 150 kW

  • Puissance créte accidentelle [2]

    5 kW

    Puissance créte accidentelle 3 I'entrée {pendant 5 mn max.) - - 150 kW

  • Puissance créte accidentelle [3]

    150 kW

    Puissance créte accidentelle 3 I'entrée {pendant 5 mn max.) - - 150 kW