Data set 01
1968 General Electric Co
Published operating points and test conditions from this source.
Tetrode
Other
The tube is capable of providing useful output at frequencies up to approximately
1500 MHz
The tube is capable of providing useful output at frequencies up to approximately 1500 megacycles.
Pulsed Drive,
1250 MHz
Pulsed Drive, 1250 Megacycles
DC Plate Voltage . . . .. .. . ittt it e it ittt et et s ettt e
3.5 kV
DC Plate Voltage . . . .. .. . ittt it e it ittt et et s ettt e 3.5 Kilovolts
DC Plate Current, during pulse . .. .. .. .. .. ..ttt eeenennnnan
5 A
DC Plate Current, during pulse . .. .. .. .. .. ..ttt eeenennnnan 5 Amperes
DC Grid-No. 2 Voltage . .. .. .. ... i ittt ittt et e ieee
750 V
DC Grid-No. 2 Voltage . .. .. .. ... i ittt ittt et e ieee . 750 Volts
DC Grid-No. 1 Voltage . .. .. .. . i it it it it it i e et et e
-200 V
DC Grid-No. 1 Voltage . .. .. .. . i it it it it it i e et et e -200 Volts
Plate Dissipation . . . . . .. .. ... i i i e e e e e e
150 W
Plate Dissipation . . . . . .. .. ... i i i e e e e e e 150 Watts
Pulse Width®O . . . . . . e e e e e
15 us
Pulse Width®O . . . . . . e e e e e 15 Microseconds
Grounded-Grid Service at
1100 MHz
Grounded-Grid Service at 1100 Megacycles, 1/4 A Qutput Circuit
DC Plate VOltage . . . . . . . . . i i it et e e et e e e et e ee o 2,5
2.5 kV
DC Plate VOltage . . . . . . . . . i i it et e e et e e e et e ee o 2,5 2.5 Kilovolts
DC Plate Current, during pulse . .. .. .. ... ... ... ... 0., 1.4
1 A
DC Plate Current, during pulse . .. .. .. ... ... ... ... 0., 1.4 1.0 Amperes
DCGrid-No. 2 Voltage . .. .. .. .. ittt et eennennsoss 600
600 V
DCGrid-No. 2 Voltage . .. .. .. .. ittt et eennennsoss 600 600 Volts
DC Grid-No. 2 Current, duringpulse. . .. .. .. .. v v vt 50
0 mA
DC Grid-No. 2 Current, duringpulse. . .. .. .. .. v v vt 50 0 Milliamperes
DCGrid-No. 1 Voltage . .. .. ... it ittt ittt erononnnnsons -70
-70 V
DCGrid-No. 1 Voltage . .. .. ... it ittt ittt erononnnnsons -70 -70 Volts
DC Grid-No. 1 Current, duringpulse ... ........ .0t veurenn 90
80 mA
DC Grid-No. 1 Current, duringpulse ... ........ .0t veurenn 90 80 Milliamperes
Driving Power at the Tube, duringpulse .................... 165
95 W
Driving Power at the Tube, duringpulse .................... 165 95 Watts
Power Qutput, during pulse (useful) ....................... 1.6
1 kW
Power Qutput, during pulse (useful) ....................... 1.6 1.0 Kilowatts
Pulse Width . . .. .. ... .. it it i ittt 6
6 us
Pulse Width . . .. .. ... .. it it i ittt 6 6 Microseconds
Diameter A
0.03 in
Diameter A - 0,030 inches
Diameter B
0.016 in
Diameter B - 0,016 inches
Diameter C
0.036 in
Diameter C - 0,036 inches
Diameter D
0.042 in
Diameter D - 0.042 inches
ment terminal diameter (C) - 0
16 in
ment terminal diameter (C) - 0. 016 inches.
Capacitance
Anode Temperature §, MaxXimuIm . « + « « v o v o v vt ittt vt e vt i et
250 C
Anode Temperature §, MaxXimuIm . « + « « v o v o v vt ittt vt e vt i et 250 C
Ceramic Temperature at Any Point, maximum
200 C
Ceramic Temperature at Any Point, maximum . .. ................... 200 C