Data set 01
1963 Siemens
Published operating points and test conditions from this source.
Tetrode
Characteristic
EmissionCurrent
380 A
UA = UG2 = UG1 = 700 V
Other
CarrierPower
270 kW
Class C; <=30 MHz
Typical Plate Voltage
12.5 kV
Class C
Typical Screen Voltage
1200 V
Class C
Typical Plate Current
28 A
Class C
Efficiency
77 percent
Class C
AFOutputPower
350 kW
Class B; two tubes push-pull