Skip to main content

Power - Tetrode (NOT beam) (over 1000V 100W) ·Tetrode

YL1490

Exceptionally high-power coaxial metal-ceramic transmitting tetrode incorporating a vapor-cooling boiler. Intended for transmitter and audio-frequency modulator duty, it combines extremely high transconductance with approximately 200 kW plate dissipation for very large installations.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
7.2 V / 1025 A

Description

Very-high-power coaxial metal-ceramic vapor-cooled tetrode with integrated boiler for transmitter and AF modulator service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
7.2 V
Nominal heater current
1025 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Tetrode

X-ray radiationInterelectrode capacitances
Transconductance
0.2 S
Amplification factor
4.3
Max plate voltage
15000 V
Max screen voltage
2200 V
Max plate dissipation
200000 W
Max screen dissipation
6600 W
Max grid dissipation
1400 W
Max cathode current
50 A

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Siemens

Published operating points and test conditions from this source.

SECTION 1

Tetrode

Characteristic

  • EmissionCurrent

    380 A

    UA = UG2 = UG1 = 700 V

Other

  • CarrierPower

    270 kW

    Class C; <=30 MHz

  • Typical Plate Voltage

    12.5 kV

    Class C

  • Typical Screen Voltage

    1200 V

    Class C

  • Typical Plate Current

    28 A

    Class C

  • Efficiency

    77 percent

    Class C

  • AFOutputPower

    350 kW

    Class B; two tubes push-pull