Data set 01
1963 Siemens
Published operating points and test conditions from this source.
Tetrode
Characteristic
Typical Plate Voltage
3000 V
Transconductance test point
Typical Screen Voltage
500 V
Transconductance test point
Typical Plate Current
500 mA
Transconductance test point
Capacitance
CathodeControlGridCapacitance
38 to 46 pF
Nominal
CathodeScreenGridCapacitance
1.9 to 2.5 pF
Nominal
ControlGridScreenGridCapacitance
56 to 64 pF
Nominal
Other
OutputPowerVision
1 kW
TV vision transmitter; 170-230 MHz
OutputPowerSound
1.7 kW
TV sound transmitter; 170-230 MHz
PowerGainVision
18.5 to - dB
TV vision transmitter; 170-230 MHz