Skip to main content

Specialized - Radiation Counter ·Rectifier

U17

Directly heated high-voltage half-wave rectifier designed to supply cathode-ray-tube and associated circuits. Its single rectifying section provides modest current at elevated voltage.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B4
Base pins
4
Nominal heater
4 V / 1 A

Description

A directly heated high-voltage half-wave rectifier capable of supplying cathode-ray-tube and associated circuits.

Socket description

European 4-pin base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B4
Base pins
4
Nominal heater voltage
4 V
Nominal heater current
1 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Max plate voltage
2500 V
Rectifier nominal output current
30 mA

Published ratings and characteristics promoted from the approved datasheet.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1937 Osram Valves

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Heater Voltage

    4 V

    Published datasheet value

  • Heater Current

    1 A

    Published datasheet value

  • Anode Voltage RMS

    2500 V

    Published datasheet value

  • Rectified DC Current

    30 mA

    Published datasheet value

Data set 02

193X Osram

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Anode RMS voltage

    2500 V

    Published datasheet value