Data set 01
1971 English Electric Valve
Published operating points and test conditions from this source.
Cathode Ray
Other
Heater voltage
6.3 V
Heater current
300 mA
Maximum anode 4 voltage
3.3 kV
Maximum anode 3/anode 1 voltage
3.3 kV
Maximum anode 2 voltage
1.5 kV
Maximum cathode current
0.3 mA
Maximum deflection electrode voltage
500 V
Typical PDA/screen voltage
12 kV
Characteristic
Screen characteristic
X screen
Capacitance
Grid to all other electrodes capacitance
6.1 pF
Cathode to all other electrodes capacitance
5.7 pF
X1 to X2 capacitance
3.1 pF
Y1 to Y2 capacitance
1.7 pF