Data set 01
1965 Sylvania Electronic Tubes Vol3
Published operating points and test conditions from this source.
Cathode Ray
Other
Heater voltage
6.3 V
Heater current
270 mA to 330 mA
Anode voltage maximum
13000 V
Grid No. 4 focus-electrode voltage range maximum rating
-550 to 1100 V
Grid No. 2 voltage maximum
550 V
Grid No. 1 negative bias maximum
-155 V
Grid No. 1 positive bias maximum
0 V
Grid No. 1 positive peak maximum
2 V
Peak heater-cathode voltage maximum
100 V
Anode voltage
- to 10000 V
Grid No. 4 focus voltage
-125 to 300 V
Grid No. 2 voltage
300 V
Grid No. 1 cutoff voltage
-60 to -40 V
Characteristic
Emission warm-up time approximately
30 s
Brightness at 100 uA anode current minimum
60 ft-L
Face transmittance approximately
92 %
Cover transmittance approximately
32 %
Combined transmittance approximately
30 %
Capacitance
Cathode to all other electrodes capacitance maximum
10 pF
Grid No. 1 to all other electrodes capacitance maximum
15 pF
External conductive coating to anode capacitance
200 to 350 pF
CircuitValue
Grid No. 1 circuit resistance maximum
1.5 Mohm