Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Cathode Ray
Characteristics
Focusing method
Electrostatic
Deflection method
Magnetic
Application
Application
Electrostatic charge printing
Specialized - Cathode Ray ·CathodeRay
Electrostatically focused, magnetically deflected monitor CRT with a flat P4 faceplate. Sylvania specifies high-voltage operation to approximately 22 kV for bright professional monitoring.
Electrostatically focused, magnetically deflected monitor CRT with flat P4 faceplate.
Small-shell Duodecal 6-contact CRT base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Special-purpose cathode-ray tube; published ratings and construction data captured.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Focusing method
Electrostatic
Deflection method
Magnetic
Application
Electrostatic charge printing
Data set 02
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Heater current
600 mA
Focusing method
Electrostatic
Deflection method
Magnetic
Maximum principal anode/accelerator voltage
22000 V
Anode voltage maximum
22000 V
Focus-electrode voltage range
-550 to +1100 V
Grid2 voltage maximum
770 V
Heater-cathode voltage maximum
200 V
Typical anode voltage
20000 V
Typical focus-electrode voltage range
0 to +300 V
Grid1 circuit resistance maximum
1.5 Mohm
Application
Electrostatically focused, magnetically deflected monitor CRT
Phosphor
P4