Data set 01
1963 Siemens
Published operating points and test conditions from this source.
Tetrode
Characteristics
Amplification factor
8
Transconductance
53000 µS
Emission current at UA = UG2 = UG1 = 300 V
35 A V
amplification factor of screen grid
8,0
at UA = 2 kV, UG2 = 600
1000V, IA = 2 A kV
Transconductance
53 mA/V mA/V
at UA = 2 kV, UG2 = 800 V, I A = 1,5
2,5 A kV
Other
Heater voltage
10 V V
Heater current
≈ 86 A A
Frequency
160 MHz MHz
Anode voltage (dc)
8,0 kV kV
Screen grid voltage (dc)
1000 V V
Control grid voltage (dc)
– 250 V V
Peak cathode current
35 A A
Anode dissipation
12 kW kW
Screen grid dissipation
240 W W
Control grid dissipation
50 W W
Frequency
150 MHz MHz
Output power
9,0 kW 1) kW
Anode voltage (dc)
7,0 kV kV
Screen grid voltage (dc)
800 V V
Control grid voltage (dc)
– 100 V 2) V
Peak control grid voltage (ac)
100 V V
Anode current (dc)
2,0 A A
Screen grid current (dc)
160 mA mA
Anode input power
14 kW A
Anode dissipation
5,0 kW kW
Screen grid dissipation
130 W W
Efficiency
64 %
Anode load resistance
2000 Ω Ω
Transmitter Tetrode
2034 CL
The metal-ceramic seals of the tube must not exceed a temperature
220 °C at any point, except a
gram
25 °C inlet temperature at a normal air pressure of 1 bar (sea level). The cooling air a
Transmitter Tetrode
2034 CL
Capacitance
Cathode/control grid
≈ 95 pF pF
Cathode/screen grid
≈ 45 pF pF
Cathode/anode
≈ 0,04 pF 1) pF
Control grid/screen grid
≈ 76 pF pF
Control grid/anode
≈ 0,32 pF 1) pF
Screen grid/anode
≈ 22 pF pF
Transmitter Tetrode
2034 CL
Cooling
Transmitter Tetrode
2034 CL