Data set 01
1963 Siemens
Published operating points and test conditions from this source.
Tetrode
Characteristics
Amplification factor
8
Transconductance
53000 µS
Other
Heater voltage
9,5 V V
Heater current
≈ 80 A A
Emission current
35 A A
Amplification factor of screen grid
8,0
UG2 = 600
1000V,
Transconductance
53 mA/V mA/V
I A = 1,5
2,5 A A
Frequency
110 MHz MHz
Anode voltage (dc)
9,0 kV kV
Screen grid voltage (dc)
1000 V V
Control grid voltage (dc)
– 250 V V
Cathode current (dc)
6,0 A A
Peak cathode current
35 A A
Anode dissipation
12 kW kW
Screen grid dissipation
270 W W
Control grid dissipation
70 W W
Frequency
≤ 110 MHz MHz
Output power
12 kW 1) kW
Anode voltage (dc)
7,5 kV kV
Screen grid voltage (dc)
800 V V
Control grid voltage (dc)
– 100 V 2) V
Peak control grid voltage (ac)
110 V V
Anode current (dc)
2,3 A A
Screen grid current (dc)
200 mA mA
Control grid current (dc)
50 mA mA
Anode input power
17,2 kW A
Drive power
5,0 W 3) W
Anode dissipation
5,2 kW kW
Screen grid dissipation
160 W W
Efficiency
70 %
Anode load resistance
1800 Ω Ω
Transmitter Tetrode
2016 CL
The temperature of the tube’s metal-ceramic seals must not
220 °C at any point and the
temperature of the internal cathode terminal must not
250 °C. These requirements can be
gram
25 °C inlet temperature at a normal air pressure of 1 bar (sea level). The cooling air a
Transmitter Tetrode
2016 CL
Capacitance
Cathode/control grid
≈ 78 pF pF
Cathode/screen grid
≈ 5,5 pF pF
Cathode/anode
≈ 0,04 pF 1) pF
Control grid/screen grid
≈ 115 pF pF
Control grid/anode
≈ 0,32 pF 1) pF
Screen grid/anode
≈ 22 pF pF
Transmitter Tetrode
2016 CL
Cooling
Transmitter Tetrode
2016 CL
Transmitter Tetrode
2016 CL