1963 Siemens
Published operating points and test conditions from this source.
Tetrode
Characteristics
Amplification factor
4.5
Transconductance
21000 µS
Amplification factor of screen grid
4,5
Transconductance
21 mA/V mA/V
I A = 0,9
1,2 A A
Other
Heater voltage
7,5 V V
Heater current
≈ 78 A A
Frequency
30 60 110 MHz MHz
Anode voltage (dc)
7,5 7,0 6,5 kV kV
Screen grid voltage (dc)
1500 1500 1500 V V
Anode current (dc)
3,0 2,8 2,6 A A
Anode dissipation
5,0 5,0 5,0 kW kW
Screen grid dissipation
250 250 250 W W
Control grid dissipation
75 75 75 W W
Frequency
≤ 30 ≤ 110 MHz MHz
Output power
16 10 kW 1) kW
Anode voltage (dc)
7,5 6,5 kV kV
Screen grid voltage (dc)
500 750 V V
Control grid voltage (dc)
– 350 – 350 V V
Peak control grid voltage (ac)
590 430 V V
Anode current (dc)
2,8 2,3 A A
Screen grid current (dc)
0,50 0,20 A A
Control grid current (dc)
0,25 0,05 A A
Anode input power
21 15 kW A
Drive power
150 25 W 1) W
Anode dissipation
5,0 5,0 kW kW
Efficiency
77 67 %
Transmitter Tetrode
2014 CL
Frequency
30 MHz MHz
Anode voltage (dc)
5,5 kV kV
Screen grid voltage (dc)
1000 V V
Anode current (dc)
2,5 A A
Anode dissipation
6,0 kW kW
Screen grid dissipation
250 W W
Control grid dissipation
75 W W
Frequency
≤ 30 MHz MHz
Carrier power
5,8 kW 1) kW
Anode voltage (dc)
5,0 kV kV
Screen grid voltage (dc)
500 V V
Control grid voltage (dc)
– 400 V V
Peak control grid voltage (ac)
520 V V
Anode current (dc)
1,4 A A
Screen grid current (dc)
0,26 A A
Control grid current (dc)
0,05 A A
Drive power
25 W 1) W
Anode dissipation
1,1 kW 2) kW
Modulation factor
100 %
Peak screen grid voltage (ac)
450 V V
Anode dissipation during modulation
1,7 kW kW
the anode dissipation increases
1,5 times the power dissipation stated for the carrier value.
Transmitter Tetrode
2014 CL
Anode voltage (dc)
7,5 kV kV
Screen grid voltage (dc)
1500 V V
Anode current (dc)
4,0 A A
Anode dissipation
6,0 kW kW
Screen grid dissipation
250 W W
Control grid dissipation
75 W W
Output power
11,5 13,5 17 17,5 kW kW
Anode voltage (dc)
4,0 5,0 6,0 7,0 kV kV
Screen grid voltage (dc)
1250 1250 1250 1250 V V
Control grid voltage (dc)
– 270 – 280 – 310 – 325 V V
between
2 tubes Ugg m 500 480 540 470 V V
Anode current (dc)
2 × 2,55 2 × 2,20 2 × 2,10 2 × 1,80 A A
Zero signal anode current (dc)
2 × 0,75 2 × 0,50 2 × 0,41 2 × 0,35 A A
Screen grid current (dc)
2 × 0,17 2 × 0,16 2 × 0,15 2 × 0,12 A A
Anode dissipation
2 × 4,20 2 × 4,20 2 × 4,20 2 × 4,20 kW kW
Effective load resistance
1500 2370 2940 4100 Ω Ω
Transmitter Tetrode
2014 CL
The temperature of the ceramic-metal parts must not
250 °C at any point.
The cooling air diagram is valid for frequencies
30 MHz at an air inlet temperature of 25 °C MHz
and a normal air pressure
1 bar. The cooling air on the anode radiator must be supplied via the a
Capacitance
Cathode/control grid, screen grid ck/g1g2
≈ 47 pF pF
Control grid/screen grid, cathode cg1/g2k
≈ 106 pF pF
Anode/cathode
≈ 0,14 pF 1) pF
Anode/control grid
≈ 0,75 pF 1) pF
Anode/screen grid, cathode ca/g2k
≈ 18 pF pF
Anode/control grid, screen grid, cathode ca/g1g2k
≈ 18 pF pF
Transmitter Tetrode
2014 CL
Cooling
Transmitter Tetrode
2014 CL
Transmitter Tetrode