Data set 01
1963 Mullard
Published operating points and test conditions from this source.
Tetrode
Other
Maximum operating frequency
225 MHz
RF operating frequency
100 MHz
ClassC
RF plate voltage
300 V
ClassC
RF screen voltage
175 V
ClassC
RF control-grid voltage
-40 V
ClassC
RF plate current per section
38 mA
ClassC
RF output power
16 W
ClassC
RF operating frequency
200 MHz
ClassC
RF plate voltage
300 V
ClassC
RF screen voltage
175 V
ClassC
RF control-grid voltage
-40 V
ClassC
RF plate current per section
38 mA
ClassC
RF output power
14 W
ClassC
RF operating frequency
175 MHz
ClassC,Modulated
RF plate voltage
200 V
ClassC,Modulated
RF screen voltage
175 V
ClassC,Modulated
RF control-grid voltage
-60 V
ClassC,Modulated
RF plate current per section
34 mA
ClassC,Modulated
RF output power
9 W
ClassC,Modulated
Heater-cathode voltage maximum
100 V
Capacitance
Plate-grid capacitance per section
0.1 pF
Push-pull input capacitance
5 pF
PushPull
Push-pull output capacitance
1.5 pF
PushPull
Grid-to-all capacitance per section
6.2 pF
Plate-to-all capacitance per section
2.6 pF
Characteristics
Grid1-to-grid2 amplification factor
7.5
Heater warm-up time
22 s
Application
Application
RF power amplifier / oscillator / frequency multiplier