Skip to main content

Specialized - Cathode Ray ·CathodeRay

MF5310

Philips/Mullard radar cathode-ray display tube with magnetic focusing and deflection, long-persistence screen characteristics, and high-voltage operation tailored to radar presentation for type MF5310.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 300 mA

Description

Large round metal-backed radar cathode-ray tube with orange screen and magnetic focusing and deflection.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
300 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

CRT-specific optical, focusing, deflection, accelerating-voltage, scan, capacitance, and safety data are retained in TUBE_SECTION_PARAMETER because the locked promoted fields primarily target conventional electrode sections.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V2

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Other

  • Heater voltage

    6.3 V

    CathodeRay

  • Heater current

    300 mA

    CathodeRay

  • Accelerator/anode voltage

    15 kV

    RadarCRT

  • Grid No.2 voltage

    300 V

    RadarCRT

  • Grid No.1 cutoff voltage minimum

    30 V

    RadarCRT

  • Grid No.1 cutoff voltage maximum

    70 V

    RadarCRT

Construction

  • Focusing

    Magnetic

    CathodeRay

  • Deflection

    Double magnetic

    CathodeRay

  • Screen color

    Orange

    CathodeRay

  • Screen persistence

    Long

    CathodeRay

  • Screen construction

    Metal-backed

    RadarCRT

Data set 02

1963 Philips Electron Tubes Handbook V3

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Construction

  • Screen color

    Orange

    RadarCRT

  • Focusing

    Magnetic

    RadarCRT

  • Deflection

    Magnetic

    RadarCRT

Characteristic

  • Light transmission

    72 %

    RadarCRT

  • Drive voltage at 100 uA beam current maximum

    45 V

    RadarCRT

Other

  • Useful screen diameter

    490.5 mm

    RadarCRT

  • Final accelerator voltage

    25 kV

    RadarCRT

  • Grid No.1 extinction voltage minimum

    -120 V

    RadarCRT

  • Grid No.1 extinction voltage maximum

    -60 V

    RadarCRT

Capacitance

  • Grid capacitance

    5 pF

    Section1

  • Cathode capacitance

    5 pF

    Section1

Data set 03

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Heater voltage

    6.3 V

  • Heater current

    300 mA

Construction

  • Useful screen diameter

    490.5 mm

  • Deflection method

    Magnetic

  • Focusing method

    Magnetic

  • Screen construction

    Metal-backed

Other

  • Operating anode voltage

    25000 V

  • Maximum anode voltage

    27000 V

Capacitance

  • Grid No.1 capacitance

    5 pF