Data set 01
1999 Philips E-Z
Published operating points and test conditions from this source.
Cathode Ray
Characteristic
MONITOR TUBES
17 cm
Face diagona!
17 cm
Neck diameter
28 mm
Overall length max
234 mm
Screen dimensions min [1]
124 mm
Screen dimensions min [2]
93 mm
Resolution min
1050 TV lines
diagonal min
165 mm
horizontal axis min
124 mm
vertical axis min
93 mm
332 November 1
987 W
Overall length 227 +
7 mm
Neck diameter min
27.8 mm
Base neo eightar, B8H; |[EC67-1
31 A
Net mass approx
0.7 kg
Final accelerator contact connector
55563 A
at V93,35(Q) =14 I'<V, Vg2
400 V
lg [1]
20 pA
lg [2]
1050 TV lines
X-radiation limit curves, at a constant anode current of
250 µA
arising from prolonged exposure at close range to this tube when operated above
14 kV
Capacitance
final accelerator to external conductive coating Cq3,95(2)/m
300 pF
cathode to all other elements Ck
3.6 pF
grid 1 to all other elements Cq1
7 pF
heater voltage Vi
63 V
heater current I¢
240 mA
current at equilibrium conditions approx
5 s
Other
* For optimum focus at a beam-current of
50 µA
the human eye, on a 312-lines raster with dimensions [1]
70 mm
the human eye, on a 312-lines raster with dimensions [2]
70 mm