Skip to main content

Specialized - Cathode Ray ·CathodeRay

M17142WE

Seventeen-centimeter high-resolution monitor CRT with magnetic deflection and electrostatic focusing. Its screen and resolution characteristics are designed for detailed professional direct-view monitoring.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
B8H
Socket code
-
Base pins
8
Nominal heater
6.3 V / 240 mA

Description

17 cm high-resolution monitor cathode-ray tube. The Philips sheet specifies magnetic deflection, electrostatic focusing, heater data, screen and resolution characteristics, capacitances, recommended operating voltages, limiting values, and X-radiation limits where published.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
B8H
Socket code
-
Base pins
8
Nominal heater voltage
6.3 V
Nominal heater current
240 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

B8H - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

17 cm high-resolution monitor cathode-ray tube

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristic

  • MONITOR TUBES

    17 cm

  • Face diagona!

    17 cm

  • Neck diameter

    28 mm

  • Overall length max

    234 mm

  • Screen dimensions min [1]

    124 mm

  • Screen dimensions min [2]

    93 mm

  • Resolution min

    1050 TV lines

  • diagonal min

    165 mm

  • horizontal axis min

    124 mm

  • vertical axis min

    93 mm

  • 332 November 1

    987 W

  • Overall length 227 +

    7 mm

  • Neck diameter min

    27.8 mm

  • Base neo eightar, B8H; |[EC67-1

    31 A

  • Net mass approx

    0.7 kg

  • Final accelerator contact connector

    55563 A

  • at V93,35(Q) =14 I'<V, Vg2

    400 V

  • lg [1]

    20 pA

  • lg [2]

    1050 TV lines

  • X-radiation limit curves, at a constant anode current of

    250 µA

  • arising from prolonged exposure at close range to this tube when operated above

    14 kV

Capacitance

  • final accelerator to external conductive coating Cq3,95(2)/m

    300 pF

  • cathode to all other elements Ck

    3.6 pF

  • grid 1 to all other elements Cq1

    7 pF

  • heater voltage Vi

    63 V

  • heater current I¢

    240 mA

  • current at equilibrium conditions approx

    5 s

Other

  • * For optimum focus at a beam-current of

    50 µA

  • the human eye, on a 312-lines raster with dimensions [1]

    70 mm

  • the human eye, on a 312-lines raster with dimensions [2]

    70 mm