Specialized - Radiation Counter ·GeigerMullerCounter

HZA1540

Halogen-quenched Siemens Geiger-Müller counter for gamma and neutron radiation. Thermal-neutron measurement uses an external cadmium foil, allowing the detector to distinguish neutron response through converter-assisted operation.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Halogen-quenched Geiger-Müller counter tube for measuring gamma and neutron radiation; thermal-neutron counting uses an external cadmium foil.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

GeigerMullerCounter

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Siemens

Published operating points and test conditions from this source.

SECTION 1

GeigerMullerCounter

Characteristics

  • Capacitance

    2 pF

  • Plateau start

    425 V

    Maximum

  • Plateau length

    225 V

    Minimum

  • Dead time

    60-110 us

Other

  • Recommended operating voltage

    450 V