Data set 01
1959 Telefunken
Published operating points and test conditions from this source.
Rectifier
Other
Typical Output Voltage
25000 V
FlybackPulse
Typical Output Current
1.5 mA
Peak Inverse Voltage
33500 V
FlybackPulse
Rectifier - TV Line Scan Boost ·Rectifier
Very-high-voltage rectifier for color-television CRT EHT supplies, with manufacturer warning of X-ray emission above approximately 18 kV.
Very-high-voltage rectifier for color-television picture-tube EHT supplies; the source warns of X-ray emission above 18 kV.
Magnoval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Single-anode EHT rectifier for color television; high-voltage limiting value promoted.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Typical Output Voltage
25000 V
FlybackPulse
Typical Output Current
1.5 mA
Peak Inverse Voltage
33500 V
FlybackPulse
Data set 02
Published operating points and test conditions from this source.
atmospheric pressure (
450 mm
Published in approved GY501 target datasheet entry; Section1
V
25000 V
Published in approved GY501 target datasheet entry; Section1
P.1. V. max. (see note 2)
31000 V
Published in approved GY501 target datasheet entry; Section1
V max
25000 V
Published in approved GY501 target datasheet entry; Section1
a _h+k
1.2 pF
Published in approved GY501 target datasheet entry; Section1
Data set 03
Published operating points and test conditions from this source.
Heater or filament voltage
3.15 V
Published nominal or stated operating value
Heater or filament current
370 mA
Published nominal or stated operating value
Rectified voltage
27.5 kV
Published maximum
X-ray warning threshold
18 kV
Source warning
Data set 04
Published operating points and test conditions from this source.
Heater voltage
3.15 V
Published nominal value
Heater current
400 mA
Published nominal value
Maximum rectified voltage
27.5 kV
Published
X-ray warning threshold
18 kV
Published warning
Data set 05
Published operating points and test conditions from this source.
D.C. output voltage v
25 kV
D.C. output voltage v 25 kV
Anode current I
1.5 mA
Anode current I 1.5 mA
Heater voltage Vr
3.15 v
Heater voltage Vr 3.15 vl
Heater current I¢
400 mA
Heater current I¢ 400 mA
Pins
5 a
Pins 1, 5 and 9 may be used to connect an anti-corona ring.
Pins
9 ma
Pins 1, 5 and 9 may be used to connect an anti-corona ring.
sistor) may be connected to pins
3 a
sistor) may be connected to pins 3 and 7. These pins must never be earthed.
I to be expected in practice, Vepmg should be
3.15 V
I to be expected in practice, Vepmg should be 3.15 V. __
Anode to cathode Caik
1.2 pF
Anode to cathode Caik 1.2 pF
Output voltage Vo
25 kv
Output voltage Vo 25 kv
Peak inverse voltage (absolute max.) Vainvp max
35 kv
Peak inverse voltage (absolute max.) Vainvp max. 35 kv 1y
Output voltage (absolute max. ) Vo max
27.5 kV
Output voltage (absolute max. ) Vo max. 27.5 kV
Output current, average Is
1.7 mA
Output current, average Is 1.7 mA
peak Iop max
100 mA
peak Iop max. 100 mA 2)
35 area of permissible operation
35 a