Tube cross-reference
ECF80 alternatives, equivalents, and replacements
Review exact electrical variations and directional substitutions recorded for the ECF80 voltage triode pentode. Compare core specifications and verify every restriction before using a replacement.
Exact variations of ECF80
These designations belong to the same electrical variation group. Their names may differ because of international standards, manufacturing tolerances, or materials, but they are recorded as electrically equivalent—not merely substitutes.
Replacement tubes for ECF80
The following tubes are recorded as possible replacements for ECF80. This direction does not establish that ECF80 can replace them.
Voltage Radio Detector Converter
The database records 6BL8 as a possible replacement forECF80.
No special restrictions are recorded for this substitution.
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Triode Pentode | Voltage Radio Detector Converter |
| Construction | Pentode-Triode | Pentode-Triode |
| Base | 9C12 | 9DC |
| Socket | B9A | B9A |
| Base pins | 9 | 9 |
| Sections | 2 | 2 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.43 A | 0.45 A |
Where ECF80 can be used as the replacement
In these recorded relationships, ECF80 is the replacement tube. The listed original tubes are not automatically suitable as replacements for ECF80.
Voltage Radio Detector Converter
The database records ECF80 as a possible replacement for6BL8.
No special restrictions are recorded for this substitution.
| Specification | ECF80 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Triode Pentode | Voltage Radio Detector Converter |
| Construction | Pentode-Triode | Pentode-Triode |
| Base | 9C12 | 9DC |
| Socket | B9A | B9A |
| Base pins | 9 | 9 |
| Sections | 2 | 2 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.43 A | 0.45 A |
Voltage Triode Pentode
The database records ECF80 as a possible replacement for6HL8.
No special restrictions are recorded for this substitution.
| Specification | ECF80 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Triode Pentode | Voltage Triode Pentode |
| Construction | Pentode-Triode | Pentode-Triode |
| Base | 9C12 | 9AE |
| Socket | B9A | B9A |
| Base pins | 9 | 9 |
| Sections | 2 | 2 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.43 A | 0.6 A |
Voltage Radio Detector Converter
The database records ECF80 as a possible replacement for6U8.
No special restrictions are recorded for this substitution.
| Specification | ECF80 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Triode Pentode | Voltage Radio Detector Converter |
| Construction | Pentode-Triode | Pentode-Triode |
| Base | 9C12 | 9AE |
| Socket | B9A | B9A |
| Base pins | 9 | 9 |
| Sections | 2 | 2 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.43 A | 0.45 A |
Verify before substituting
Matching a base or heater voltage is not enough to prove that two tubes are interchangeable. Check pin connections, heater current, maximum ratings, bias requirements, warm-up behavior, and the equipment manufacturer’s service documentation before making a substitution.
View the complete ECF80 specifications →