Specialized - Cathode Ray ·CathodeRay

DN94

Philips high-vacuum oscillography CRT with electrostatic beam control and a long-persistence display screen. The persistent trace is intended for measurements where waveforms must remain visible after the writing beam passes.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
B12A
Base pins
-
Nominal heater
4 V / 1 A

Description

The Philips DN94 is a high-vacuum oscillography crt with persistent.

Socket description

Duodecal 12-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B12A
Base pins
-
Nominal heater voltage
4 V
Nominal heater current
1 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances
Max plate voltage
1200 V

High-vacuum CRT with electrostatic focusing and symmetrical double electrostatic deflection. Screen variant: persistent.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1957 Philips Receiving and Amplifying Tubes

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Heater Voltage

    4 V

  • Heater Current

    1 A

  • Phosphor Variant

    persistent text

    Screen fluorescence and persistence

Data set 02

1963 Philips Electron Tubes Handbook V2

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Capacitance

  • Capacitances Cg

    8 pF

    Capacitances Cg = 8 pF

Data set 03

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristic

  • Heating: indirect by A.C. VE

    4 V

    Published datasheet condition

  • Chauffage: indirect par C.A. If = 1’

    0 mA

    Published datasheet condition

  • CD1'

    9.5 pF

    Published datasheet condition

  • CDZ

    10 pF

    Published datasheet condition

  • Cpoe

    10 pF

    Published datasheet condition

  • CD2D2'

    1.3 pF

    Published datasheet condition

  • Epaisseur de la ligne %¥a2 Z 1802 Xg

    0.7 mm

    Published datasheet condition

  • Va2

    1000 V

    Published datasheet condition

  • Val = 200

    400 V

    Published datasheet condition

  • Vg = 0

    40 V

    Published datasheet condition

  • N1

    0.4 mm

    Published datasheet condition

  • N2

    0.31 mm

    Published datasheet condition

  • } Measured on a circle of

    50 mm

    Published datasheet condition

  • Mesuré & un cercle de

    50 mm

    Published datasheet condition

  • Gemessen an einem Kreis von

    50 mm

    Published datasheet condition

  • 10

    10.1949 A

    Published datasheet condition

  • Published value

    3 A

    Published datasheet condition

Other

  • Va2

    1200 V

    Published datasheet condition

  • Va1l

    500 V

    Published datasheet condition

  • Vg

    200 V

    Published datasheet condition

  • VD1D1Ip

    350 V

    Published datasheet condition

  • VD2D2'p

    450 V

    Published datasheet condition

  • W)

    3 mW

    Published datasheet condition