Data set 01
1963 Philips Electron Tubes Handbook V2
Published operating points and test conditions from this source.
Cathode Ray
Construction
Focusing
Electrostatic
OscilloscopeCRT
Deflection
Double electrostatic
OscilloscopeCRT
Screen fluorescence
Green to blue
OscilloscopeCRT
Screen persistence
Short
OscilloscopeCRT
Other
Heater voltage
6.3 V
OscilloscopeCRT
Heater current
550 mA
OscilloscopeCRT
Accelerator voltage
1000 V
OscilloscopeCRT
Focusing voltage minimum
210 V
OscilloscopeCRT
Focusing voltage maximum
320 V
OscilloscopeCRT
Grid No.1 voltage minimum
-65 V
OscilloscopeCRT
Grid No.1 voltage maximum
-28 V
OscilloscopeCRT
Characteristic
D1 sensitivity
0.87 mm/V
OscilloscopeCRT
D2 sensitivity
0.5 mm/V
OscilloscopeCRT
Sensitivity limit D2 minimum
410 mm/V per kV
OscilloscopeCRT
Sensitivity limit D2 maximum
610 mm/V per kV
OscilloscopeCRT
Sensitivity limit D1 minimum
685 mm/V per kV
OscilloscopeCRT
Sensitivity limit D1 maximum
1050 mm/V per kV
OscilloscopeCRT