Skip to main content

Specialized - Cathode Ray ·CathodeRay

DB76

Philips DB-series electrostatic cathode-ray instrument tube for oscillographic and measurement display, with manufacturer-defined screen persistence, focusing, deflection, and accelerating characteristics for type DB76.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
B8G
Base pins
-
Nominal heater
6.3 V / 300 mA

Description

The Mullard DB76 is a high-vacuum electrostatic oscilloscope tube with an approximately 2.5-inch screen and blue short persistence phosphor.

Socket description

Loctal 8-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B8G
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
300 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances
Max plate voltage
1000 V

Cathode-ray electron-gun/display system; electrostatic deflection and capacitance data published.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

194X Miniwatt

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Other

  • FinalAcceleratingVoltage

    800 V

Data set 02

1951 Mullard Valve and Service Manual

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristic

  • Screen Colour / Persistence

    Blue, short persistence

  • Focusing Method

    Electrostatic

  • Deflecting Method

    Double Electrostatic

Other

  • Anode Voltage

    800 V

  • Focusing Electrode Voltage Minimum

    200 V

  • Focusing Electrode Voltage Maximum

    300 V

Data set 03

1957 Philips Receiving and Amplifying Tubes

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Other

  • Maximum Plate Voltage

    400 V

  • Grid 2 Operating Voltage Minimum

    200 V

  • Grid 2 Operating Voltage Maximum

    300 V

  • Maximum Grid 2 Voltage

    400 V

Characteristic

  • Focusing Method

    Electrostatic

  • Deflection Method

    Double electrostatic

  • Screen Variant

    blue, short persistence

Data set 04

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristic

  • Heating: indirect by A.C. or D.C. Ve

    6.3 V

    Published datasheet condition

  • Heizung: indirekt durch Wechsel- Ifr

    400 mA

    Published datasheet condition

  • Dep2! asymmetr. D2' 801l mit a

    2 v

    Published datasheet condition

  • DG 7

    -6 v

    Published datasheet condition

  • DN 7

    -6 v

    Published datasheet condition

  • Heating : indirect by A.C. or D.C. Ve

    6.3 V

    Published datasheet condition

  • Chauffage:; indirect par C.A. ou C.C, Ve = &

    3 V

    Published datasheet condition

  • Chauffage: indirect par C.A. ou C.C. Ve o= &

    3 V

    Published datasheet condition

  • Capacitances Cg

    9 pF

    Published datasheet condition

  • Kapazitéten o1

    4.8 pF

    Published datasheet condition

  • Cp1

    4.8 pF

    Published datasheet condition

  • Cp2

    5 pF

    Published datasheet condition

  • Cp2*

    544 PF

    Published datasheet condition

  • Cp1D1°

    0.6 pF

    Published datasheet condition

  • Cp2p2*

    0.8 pF

    Published datasheet condition

  • CD1D1'-D2p2*

    0.1 pF

    Published datasheet condition

  • Epaisseur de la ligne §¥a2 = gog VA{

    0.7 ma

    Published datasheet condition

  • Va2

    800 V

    Published datasheet condition

  • Va1t = 200

    -300 V

    Published datasheet condition

  • Vg = 0

    50 V

    Published datasheet condition

  • Ny

    0.26 mm

    Published datasheet condition

  • N2

    0.16 mm

    Published datasheet condition

  • 1) NMeasured on a circle of

    50 mm

    Published datasheet condition

  • Measuré & un cercle de

    50 mm

    Published datasheet condition

  • Gemessen an einem Kreis von

    50 mm

    Published datasheet condition

  • Ca1

    10 pF

    Published datasheet condition

  • Ca1 = 10 pF CD2'

    4.5 pF

    Published datasheet condition

  • CD‘I

    5.3 pF

    Published datasheet condition

  • CD‘I = 5,3 pF cD1D1'

    0.6 pF

    Published datasheet condition

  • cD‘l'

    5.3 pF

    Published datasheet condition

  • cD‘l' = 5,3 pF CDZDZ'

    18 pF

    Published datasheet condition

  • Cpa = 415 9F Cpypyr_pepar= O»

    1 PF

    Published datasheet condition

  • Vg3

    800 V

    Published datasheet condition

  • Vg2 = 200

    -300 V

    Published datasheet condition

  • N4

    0.25 mm

    Published datasheet condition

  • N»

    0.16 mm

    Published datasheet condition

  • 1) Measured‘on a circle of

    50 mm

    Published datasheet condition

  • Mesuré & un cercle de

    50 mm

    Published datasheet condition

  • Cg1

    10 pF

    Published datasheet condition

  • Cg1 = 10 pF CD2l

    4.5 pF

    Published datasheet condition

  • Cp

    5.3 pF

    Published datasheet condition

  • Cp = 5,3 pF CD1D1'

    0.6 pF

    Published datasheet condition

  • CD1'

    5.3 pF

    Published datasheet condition

  • CD1' = 5,3 pF CD2D2‘

    0.8 pF

    Published datasheet condition

  • Epaisseur de la ligne E¥g3 - gog vAg

    0.7 mm

    Published datasheet condition

  • Vgo = 200

    -300 V

    Published datasheet condition

  • Vg1 = 0

    -50 V

    Published datasheet condition

  • X1

    0.25 mm

    Published datasheet condition

  • Np

    0.16 mm

    Published datasheet condition

  • 3 6800

    1 V

    Published datasheet condition

  • Published value

    750 V

    Published datasheet condition

  • 1) leasured on a circle of

    50 mm

    Published datasheet condition

  • Mesuré 4 un cercle de

    50 mm

    Published datasheet condition

  • Gemessen an einem Kreis voun

    50 mm

    Published datasheet condition

  • Ca1

    7 pF

    Published datasheet condition

  • Ca1 = 7,0pF CDQ'

    2.8 pF

    Published datasheet condition

  • CD‘]

    3.2 pF

    Published datasheet condition

  • CD‘] = 3,2pF cD1D1'

    0.7 pF

    Published datasheet condition

  • Cpir = 3,509F Cp2p2

    0.9 pF

    Published datasheet condition

  • CD2

    3 pF

    Published datasheet condition

  • Vg2 = 200~

    -300 V

    Published datasheet condition

  • N¢

    0.25 mm

    Published datasheet condition

  • 1) Measured on a circle of

    50 mm

    Published datasheet condition

  • Gemessen an einem Ereis von

    50 mm

    Published datasheet condition

  • O N

    759 A

    Published datasheet condition

Other

  • Grenzdaten Yoz _

    1000 V

    Published datasheet condition

  • Published value

    800 V

    Published datasheet condition

  • Va1

    400 V

    Published datasheet condition

  • Vg

    100 V

    Published datasheet condition

  • "’D1D1'p

    450 V

    Published datasheet condition

  • vD2D2'p

    750 V

    Published datasheet condition

  • Wy

    3 mW

    Published datasheet condition

  • Vg3

    1000 V

    Published datasheet condition

  • Vg3 = max. 1000 V vD1D1'p = maxXe

    450 V

    Published datasheet condition

  • Vg3 = min. 800 V Vpoppr,,

    750 V

    Published datasheet condition

  • Vg2

    400 V

    Published datasheet condition

  • Vg2 = max. 400V We L

    3 mw

    Published datasheet condition

  • Vg1

    100 V

    Published datasheet condition

  • Vg1 = max. 100V Rg1

    0.5 MΩ

    Published datasheet condition

  • Vg3 = max. 1000 ¥ VD7D1 p

    450 V

    Published datasheet condition

  • Vg2 = max. 400V Vip

    3 mW

    Published datasheet condition

  • ~Vg1

    100 V

    Published datasheet condition

  • ~Vg1 = max. 100V Rg1

    0.5 MΩ

    Published datasheet condition

  • Vg3 =min. 800 V VD2D2'p

    750 V

    Published datasheet condition

  • Vg1 = max. ov Rp

    5 MΩ

    Published datasheet condition

  • Vg1 = max. 100V Rgq

    0.5 MΩ

    Published datasheet condition