Data set 01
1957 Philips Receiving and Amplifying Tubes
Published operating points and test conditions from this source.
Cathode Ray
Characteristic
Heater Voltage
6.3 V
Heater Current
600 mA
DeflectionMethod
Electrostatic
Specialized - Cathode Ray ·CathodeRay
Philips cathode-ray oscilloscope tube for oscillography, using electrostatic beam control. Manufacturer documentation provides screen, focusing and deflection, capacitance, sensitivity, rating, and operating data where published.
High-sensitivity oscillography cathode-ray tube with electrostatic deflection.
Duodecal 12-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Electrostatic focusing/deflection CRT section; electrical/screen/deflection data retained in parameter rows.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
600 mA
DeflectionMethod
Electrostatic
Data set 02
Published operating points and test conditions from this source.
Deflection sensitivity N1 without post-acceleration
0.68 to 0.84 mm/V
Deflection sensitivity N2 without post-acceleration
0.51 to 0.63 mm/V
Deflection sensitivity N1 with post-acceleration
0.51 to 0.63 mm/V
Deflection sensitivity N2 with post-acceleration
0.38 to 0.47 mm/V
Maximum post-acceleration voltage
6000 V
Maximum main accelerating voltage
2600 V
Minimum main accelerating voltage
1000 V
Maximum focusing-grid voltage
1000 V
Maximum heater-cathode voltage
180 V
Data set 03
Published operating points and test conditions from this source.
Accelerator voltage
2600 V
Minimum accelerator voltage
1000 V
Maximum post-acceleration ratio
2.3