Data set 01
1963 Philips Electron Tubes Handbook V2
Published operating points and test conditions from this source.
Cathode Ray
Other
Useful screen diameter min
114 mm
Useful screen diameter min. 114 mm
The useful scan may vertically be shifted max
3 mm
The useful scan may vertically be shifted max. 3 mm with
Cathode to all other electrodes CM = max
3.5 pF
Cathode to all other electrodes CM = max. 3.5 pF
Isolation shield voltage Vç max
4400 V
Isolation shield voltage Vç max. 4400 V
voltage Vg
4200 V
voltage Vg5 = max. 4200 V
Focusing electrode voltage Vg
2000 V
Focusing electrode voltage Vg3 = max. 2000 V
cathode positive Vkf(k pos) = max
200 V
cathode positive Vkf(k pos) = max. 200 V
cathode negative Vkf(k neg) = max
125 V
cathode negative Vkf(k neg) = max. 125 V
Cathode current Ik = max
1.5 mA
Cathode current Ik = max. 1.5 mA(RMS)
Characteristic
Heater voltage Vg
6.3 V
Heater voltage Vg = 6.3 V
Heater current If
300 mA
Heater current If = 0.3 A
Post accelerator voltage
24 kV
Post accelerator voltage = 24 kV
Grids No
4 kV
Grids No. 2 and 4 voltage VB2iB4 = 4 kV
Beam current IJ
10 µA
Beam current IJ = 10 µA
Line width l.w
0.2 mm
Line width l.w. = 0.2 mm
Post accelerator voltage Vg
24 kV
Post accelerator voltage Vg. = 24 kV
Isolation shield voltage
4000 V
Isolation shield voltage = 4000 V t)
Deflection plate shield voltage
200 V
Deflection plate shield voltage = 4000 ± 200 V 1 )
Accelerator voltage VB
200 V
Accelerator voltage VB2,g4 = 4000 ± 200 V 1 )
Focusing electrode voltage
1400 V
Focusing electrode voltage = 800 to 1400 V
Grid No
-192 V
Grid No.1 voltage V51 = -120 to -192 V 2)
Accelerator voltage yg
4200 V
Accelerator voltage yg2,g4 = 4200 V