Data set 01
195X AEG Telefunken
Published operating points and test conditions from this source.
Cathode Ray
Other
Mean Deflection Plate Potential
2000 V
Published typical operating condition or characteristic from the approved datasheet.
Acceleration Voltage
2000 V
Published typical operating condition or characteristic from the approved datasheet.
Wehnelt Voltage for Spot Cut-off
-35 to -18 V
Published typical operating condition or characteristic from the approved datasheet.
Modulation Voltage
15 V
Published typical operating condition or characteristic from the approved datasheet.
Focusing Voltage
150 to 250 V
Published typical operating condition or characteristic from the approved datasheet.
Astigmatism Correction Voltage
1900 to 2100 V
Published typical operating condition or characteristic from the approved datasheet.
Heater Voltage
0.55 V
Published heater rating.
Heater Current
60 mA
Published heater rating.
Characteristic
Deflection Coefficient X
90 to 110 V/cm
Published typical operating condition or characteristic from the approved datasheet.
Deflection Coefficient Y
90 to 110 V/cm
Published typical operating condition or characteristic from the approved datasheet.
Useful Scan X
40 mm
Published typical operating condition or characteristic from the approved datasheet.
Useful Scan Y
30 mm
Published typical operating condition or characteristic from the approved datasheet.