Data set 01
1999 Philips 0-D
Published operating points and test conditions from this source.
Cathode Ray
Other
Heater voltage
6.3 V
Nominal
Heater current
240 mA
Nominal
Characteristic
for oscilloscopes with up to
500 MHz
Published datasheet value
Final accelerator voltage Vg7(g
24 kV
Published datasheet value
First accelerator voltage V9
2 kv
Published datasheet value
Minimum useful scan area
100 mm
Published datasheet value
horizontal M,
7.3 V/cm
Published datasheet value
vertical My
2.9 V/cm
Published datasheet value
Photographic writing speed p.w.s. min,
3 s
Published datasheet value
Useful scan area
2 mm
Published datasheet value
Heater voltage Vs
6.3 V
Published datasheet value
Heater current ¥
240 mA
Published datasheet value
Heating time to attain
10 a
Published datasheet value
at equilibrium conditions approx
5 s
Published datasheet value
Overall length (socket included) <
419 mm
Published datasheet value
Faceplate dimensions
118 mm
Published datasheet value
Base
12 a
Published datasheet value
Side contact connector for ¢
0.65 mm
Published datasheet value
Side contact connector for ¢
0.45 mm
Published datasheet value
Bandwidth of helix system {(—
3 a
Published datasheet value
X1 to all other elements except x2 Cx1(x2
3.2 pF
Published datasheet value
x2 to all other elements except x1 Cx2(x1
3.2 pF
Published datasheet value
x1 to xp Cxi1x2
3 pF
Published datasheet value
X1 toyy Cx1y1 <
0.2 pF
Published datasheet value
x2 toyq Cx2y1 <
2 pF
Published datasheet value
X1
10 pF
Published datasheet value
x2toys Cx2y2 <
0.2 pF
Published datasheet value
Control grid to all other elements Cg1
6.2 pF
Published datasheet value
Cathode to all other elements Ck
3.8 pF
Published datasheet value
Focusing electrode to all other elements Cg3
76 pF
Published datasheet value