Skip to main content

Specialized - Cathode Ray ·CathodeRay

D1315GM

Philips high-sensitivity metal-backed oscilloscope CRT with helical post-deflection acceleration, designed for bright, accurately controlled waveform presentation.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 300 mA

Description

D1315GM is a Philips high-sensitivity metal-backed oscilloscope CRT with helical post-deflection acceleration. The supplied datasheet provides electrostatic-deflection, focusing, acceleration, screen and operating characteristics.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
300 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Electrostatic deflection, accelerator/focus/grid voltages, sensitivities and limiting values reviewed.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V2

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristic

  • Heater voltage

    6.3 V

    Published heater rating

  • Heater current

    300 mA

    Published heater rating

  • Screen fluorescence

    Purplish blue

    Screen

  • Screen phosphorescence

    Yellowish green

    Screen

  • Screen persistence

    Long

    Screen

  • Useful screen diameter

    114 mm

    Minimum

  • Useful horizontal scan

    100 mm

    Minimum

  • Useful vertical scan

    60 mm

    Minimum

  • Horizontal deflection factor

    21 to 26 V/cm

    OscilloscopeCRT

  • Vertical deflection factor

    5.1 to 6.7 V/cm

    OscilloscopeCRT

Other

  • Post-accelerator voltage

    4000 V

    OscilloscopeCRT

  • Isolation-shield voltage

    2000 ± 200 V

    OscilloscopeCRT

  • Deflection-plate shield voltage

    2000 ± 100 V

    OscilloscopeCRT

  • Second-accelerator voltage

    2000 ± 100 V

    OscilloscopeCRT

  • Focusing-electrode voltage

    220 to 710 V

    OscilloscopeCRT

  • First-accelerator voltage

    2000 V

    OscilloscopeCRT

  • Grid No.1 voltage

    -60 to -96 V

    OscilloscopeCRT

  • Maximum deflection-linearity deviation

    2 %

    OscilloscopeCRT