Data set 01
1963 Philips Electron Tubes Handbook V2
Published operating points and test conditions from this source.
Cathode Ray
Construction
Screen color
Yellowish green
OscilloscopeCRT
Screen persistence
Medium short
OscilloscopeCRT
Focusing
Electrostatic
OscilloscopeCRT
Deflection
Double electrostatic
OscilloscopeCRT
Other
Useful screen diameter
90 mm
OscilloscopeCRT
Useful vertical scan
60 mm
OscilloscopeCRT
Post accelerator voltage
4000 V
OscilloscopeCRT
Isolation shield voltage
1000 V
OscilloscopeCRT
Second accelerator voltage
1000 V
OscilloscopeCRT
Focusing electrode voltage minimum
20 V
OscilloscopeCRT
Focusing electrode voltage maximum
200 V
OscilloscopeCRT
First accelerator voltage
1000 V
OscilloscopeCRT
Grid No.1 voltage minimum
-67 V
OscilloscopeCRT
Grid No.1 voltage maximum
-25 V
OscilloscopeCRT
Post accelerator voltage maximum
5000 V
OscilloscopeCRT
Grid No.1 negative voltage maximum
200 V
OscilloscopeCRT
Characteristic
Horizontal deflection factor maximum
31 V/cm
OscilloscopeCRT
Vertical deflection factor maximum
11.2 V/cm
OscilloscopeCRT
Line width
0.35 mm
BeamCurrent10uA
Deflection linearity deviation maximum
2 %
OscilloscopeCRT
Pattern distortion maximum
2 %
OscilloscopeCRT
Capacitance
Grid No.1 capacitance
4 pF
Section1
Cathode capacitance
3 pF
Section1
X plate capacitance
4 pF
Section1
Y plate capacitance
3 pF
Section1