Data set 01
1958 Amperex Industrial
Published operating points and test conditions from this source.
Tetrode
Characteristic
Filament voltage
6.3 V
Published transmitting-tube rating
Filament current
33.5 A
Published transmitting-tube rating
Amplification factor
7.5
Published power-tube table
Other
Maximum plate dissipation
5000 W
Published power-tube table
Plate voltage
4000 V
TransmittingService
Plate current
1.1 A
TransmittingService
Power output
3300 W
TransmittingService
Grid bias
-250 V
TransmittingService
Grid current
70 mA
TransmittingService
Screen voltage
800 V
TransmittingService
Maximum frequency
220 MHz
FullInputWatts
Alternate plate voltage
5000 V
TransmittingService OperatingPoint2
Alternate plate current
1.1 A
TransmittingService OperatingPoint2
Alternate power output
4100 W
TransmittingService OperatingPoint2
Alternate grid bias
-250 V
TransmittingService OperatingPoint2
Alternate grid current
70 mA
TransmittingService OperatingPoint2
Alternate screen voltage
800 V
TransmittingService OperatingPoint2
Alternate maximum frequency
75 MHz
TransmittingService OperatingPoint2