Data set 01
1965 Eimac Tube Manual
Published operating points and test conditions from this source.
Tetrode
Other
Frequency Maximum
30 MHz
Typical Plate Voltage
15000 V
Typical Screen Voltage
1500 V
Typical Plate Output Power
100000 W
Water Flow at 50kW Dissipation
15.2 gpm
Water Outlet Temperature Maximum
70 C